Combined Drainage Systems in Building Construction
A combined drainage system is a single pipe network that carries both foul water (from toilets, washbasins, and showers) and surface water (from roofs, courtyards, and paved areas) to the main sewer or septic tank. In Tanzania, this system is commonly used in residential buildings, schools, and small commercial structures because it is cost-effective and easier to install than separate systems.
- Single network: Both foul and surface water flow through the same pipe network
- One outlet: All wastewater exits through a single connection to the main sewer or soakaway pit
- Shared gradients: The entire system uses a consistent fall to ensure proper flow
- Simpler design: Requires fewer pipes and inspection chambers compared to separate systems
Advantages
- Lower material and installation costs
- Simpler pipe layout requiring less excavation
- Fewer inspection chambers needed
- Suitable for areas with limited space
Disadvantages
- Risk of foul odours if not properly ventilated
- Higher likelihood of blockages when compared to separate systems
- Cannot be used in areas where separate systems are required by local authority regulations
- Surface water may overwhelm the system during heavy rains
- Pipe size: Must be large enough to handle expected flow volumes
- Gradient: Pipes must be laid at proper fall (typically 1:40 to 1:60 for 100mm pipes)
- Location: System must be at safe distance from water sources and buildings
- Ventilation: Proper venting prevents trap seal loss and odours
- Ground conditions: Soil type affects trench preparation and bedding
- Local regulations: Must comply with NEMC and local council requirements
| Pipe Type | Common Sizes | Application |
|---|---|---|
| Cast Iron | 100mm, 150mm | Main runs, below ground |
| PVC (UPVC) | 100mm, 150mm | Main runs, above ground |
| Pitch Fiber | 100mm | Main underground runs |
For most residential buildings in Tanzania, a 100mm diameter pipe serves as the main combined drain, while 75mm pipes connect individual fixtures.
Step 1: Site Preparation
- Mark out the drainage path according to the plan
- Excavate trench to required depth (minimum 600mm below ground level)
- Ensure trench bottom is firm and level
Step 2: Pipe Laying
- Lay pipes with sockets facing upstream (against the flow direction)
- Use a spirit level to check and maintain proper gradient
- Connect pipes using appropriate couplings (elbows for bends, T-junctions for branch connections)
Step 3: Jointing and Testing
- Apply jointing compound or rubber seals properly
- Backfill in layers, compacting each layer to prevent settlement
- Conduct a water test by blocking the outlet and filling the system
Step 4: Inspection Chambers
- Install inspection chambers at junctions, changes in direction, and at intervals not exceeding 30 metres
- Ensure chambers are properly sealed and have covers that can be accessed for maintenance
- Regular inspection: Check inspection chambers quarterly for blockages
- Clear blockages: Use drain rods or mechanical cleaners when needed
- Ventilation check: Ensure vent pipes are unblocked and working
- Seal repairs: Replace damaged seals or cracked pipes immediately
A primary school in Dodoma needs to install a combined drainage system connecting three toilet blocks to a septic tank located 25 metres away. The architect specifies 100mm PVC pipes with a gradient of 1:50.
Calculation: For a 25-metre run at 1:50 gradient: Fall=5025=0.5m=500mm
The trench at the outlet end must be 500mm deeper than at the inlet end to maintain proper flow. Students would need to excavate the trench to ensure this fall is achieved throughout the installation.
Always wear appropriate PPE when installing or maintaining drainage systems:
- Safety boots
- Gloves
- Safety helmet
- High-visibility vest
- Dust mask when working in trenches
A small hotel owner in Mwanza planning to expand their building with five additional guest rooms must install a combined drainage system to connect the new bathrooms to the existing septic tank. Using knowledge of combined systems, the owner can assess quotations from plumbers, ensure proper pipe sizing is specified (100mm minimum for the main line), and verify that the gradient meets Tanzanian building standards — helping avoid costly repairs and drainage problems later.
How you'll be assessedProcess assessment · Outcome assessment · Knowledge assessment
Process assessment
The student should be able to:
- Interpret working drawings.
- Identify tools
- Select materials
- Determine drain fall
- Lay drain
- Perform drain test
- Backfill the trench
- Connect pipes to sewerage disposal
- Clean the work place.
- Clean tool and store in a safe place
Outcome assessment
Combined system installed and maintained as per specification.
Knowledge assessment
Knowledge evidence:
Detailed knowledge of:
Method used: The student should explain: -
- How to install and maintain combined system.
Principles: The student should explain principles of:
- Installing combined system.
Theories: The student should explain: -
- Advantages of combined system
- Components of combine system
- Application/location of combine system
Circumstantial knowledge:
Detailed knowledge about:
- Safety precautions to be observed while maintaining combined system.
- First aid
Question
What is a combined drainage system?
Sign in to submit your answer and have it count toward your mastery.