Installing a Varistor (VARISTO R) in the Field Winding
A varistor is a voltage-dependent resistor (VDR) that protects electrical machines from overvoltage spikes. In a DC motor, the field winding is sensitive to sudden voltage surges that can damage the insulation and burn the winding. Installing a varistor across the field winding clamps the voltage to a safe level, preventing damage and extending the motor's life.
- Voltage Clamping: When the voltage exceeds the varistor's breakdown voltage, its resistance drops dramatically, shunting the excess current to ground.
- Protection from Inductive Spikes: When the motor is switched off, the collapsing magnetic field in the field winding generates a high voltage that can damage the winding insulation. The varistor absorbs this spike.
- Transient Suppression: It protects against lightning strikes, switching transients, and other voltage surges from the power supply.
The varistor is always connected across (in parallel with) the field winding terminals. This ensures that any voltage appearing across the field winding also appears across the varistor, so it can act immediately when an overvoltage occurs.
Schematic representation:
+----------------+
| |
[F+ ]---[Field ]---[F-]
| Winding |
| |
[Varistor] (connected in parallel)
| |
+----------------+
-
Safety First: Put on safety goggles, safety boots, leather gloves, and overalls before starting any work on electrical machines.
-
Inspect the Motor: Check the DC motor's nameplate data and identify the field winding terminals (usually marked F+ and F-).
-
Select the Correct Varistor: Choose a varistor with a voltage rating slightly higher than the normal operating voltage of the field winding. For example, if the field voltage is 220V, select a varistor rated at about 270V.
-
Prepare the Leads: Strip the insulation from the varistor leads using an electrician knife. Use diagonal cutting pliers to trim any excess wire.
-
Connect the Varistor: Connect one lead of the varistor to terminal F+ and the other lead to terminal F-. Use a screwdriver to secure the connections firmly. The connection must be in parallel with the field winding.
-
Secure the Connections: Use combination pliers to ensure the wire ends are properly seated in the terminals. Avoid loose connections which can cause sparking.
-
Test the Installation:
- Use a multimeter to verify continuity between the varistor leads and the field terminals.
- Use a Megger or insulation tester to check that insulation resistance is adequate between the winding and the motor frame.
A DC motor in a solar water pumping system has a field winding rated at 110V. The installer needs to protect this winding from voltage surges.
Solution:
- Identify the field winding voltage: 110V
- Select a varistor with a breakdown voltage about 1.5 times higher: 110V × 1.5 = 165V
- Choose the nearest standard rating: 180V or 200V varistor
- Connect the varistor in parallel across the field terminals (F+ and F-)
- Test the installation with a multimeter for continuity and an insulation tester for safety
- Always disconnect the power supply before working on the motor.
- Wear approved personal protective equipment (PPE) including safety goggles, gloves, and boots.
- Ensure the work area is clean and free from moisture.
- Use insulated tools for all electrical connections.
- After installation, always test insulation resistance before powering the motor.
In many rural Tanzanian villages, solar-powered water pumps use DC motors for irrigation. During rainy seasons, voltage surges from lightning or fluctuating solar input can damage the pump motor. A technician at a small solar installation business in Mwanza would install varistors in the field windings of these pumps to protect them, reducing repair costs and ensuring farmers have reliable water supply for their vegetable farms throughout the year.
How you'll be assessedProcess assessment · Outcome assessment · Knowledge assessment
Process assessment
The students should be able to explain how to:
- Interpret wiring diagrams.
- Install VARISTOR in the field winding of DC machine.
- terminate cables
- Test the D.C. machine control.
- Observe safety precautions.
- Clean the work place.
- Store tools, equipment and safety gear.
Outcome assessment
D.C. VARISTOR is installed in the field winding of DC machine as per manufacturer's specifications.
Knowledge assessment
Knowledge evidence:
Detailed knowledge of:
Methods used: The students should explain how to:
- Install single phase D.C. machine control.
- Install three phase D.C. machine control.
Principles: The students should explain the principles of: Operation of D.C. machines.
Theories: The students should explain:
- The types of a D.C. machine control.
- The major parts of D.C. machine control.
- The application of D.C. machine control.
Question
What is the main function of installing a varistor (VARISTO R) in the field winding of a DC motor?
Sign in to submit your answer and have it count toward your mastery.
Sign in to practiceTutor
Stuck? Ask me anything about this topic.
Sign in to ask the Sonza AI Tutor about this question.
Sign in to askDiscussions
No questions yet