Topics in this sectionServicing compressor above 60 kW7 topics
In refrigeration and air conditioning systems, especially when servicing compressors above 60 kW, measuring electrical quantities is essential for diagnosing faults, ensuring safe operation, and verifying that the system runs efficiently. Electrical quantities such as voltage, current, resistance, and power tell us whether the compressor motor is receiving the correct supply, drawing the right amount of current, and whether the windings are healthy.
When servicing compressors, you will measure these four main electrical quantities:
- Voltage (V) – the electrical pressure that pushes current through the circuit. In Tanzania, single-phase supplies are 230 V and three-phase are 400 V.
- Current (A) – the amount of electric charge flowing through the circuit. Compressors above 60 kW usually draw high current, so a clamp meter is often used.
- Resistance (Ω) – the opposition to current flow in the motor windings. Abnormal resistance indicates winding faults or short circuits.
- Power (W) – the rate at which electrical energy is used. It can be calculated from voltage and current.
| Tool | What it Measures | Use in Compressor Servicing |
|---|---|---|
| Digital Multimeter | Voltage, Current, Resistance | Testing supply voltage, winding resistance, continuity |
| Clamp Meter | Current (without breaking circuit) | Measuring compressor run current safely |
| Megohmmeter | Insulation resistance | Checking motor winding insulation quality |
Always wear working hand gloves and ensure the power supply is off before measuring resistance or insulation.
- Prepare the work area – Switch off the compressor and lock out the power supply. Use the inspection lamp to see clearly.
- Measure voltage – Set the multimeter to AC voltage. Place probes across the supply terminals. The reading should match the nameplate rating (230 V or 400 V ±10%).
- Measure current – Use a clamp meter. Clamp around one live conductor. Compare the reading with the nameplate full-load amperage (FLA). A higher reading suggests overloading or mechanical binding.
- Measure resistance – Set the multimeter to ohms. Disconnect the compressor from the supply. Measure resistance between each pair of motor terminals (U-V, V-W, W-U). All three readings should be nearly equal. A very low reading indicates a short circuit; an infinite reading indicates an open circuit.
- Calculate power – If you have voltage and current readings, calculate apparent power using the formula:
P=V×I
For single-phase: P=230 V×measured current (A)
For three-phase: P=3×V×I×Power Factor
A three-phase industrial air conditioning compressor in Dar es Salaam shows the following readings:
- Supply voltage: 395 V (line-to-line)
- Run current: 85 A per phase
- Measured resistance between two terminals: 0.8 Ω
Step 1: Check if voltage is acceptable. The supply is 400 V ±10%, so 395 V is within range.
Step 2: The measured resistance of 0.8 Ω is reasonable for compressor windings. If one phase read infinity, the winding would be open.
Step 3: Calculate the apparent power:
P=3×395×85≈1.73×395×85≈58,200 W≈58.2 kW
This is close to a 60 kW compressor, so the readings are normal.
- Always de-energize the system before measuring resistance.
- Use insulated tools and wear hand gloves.
- Keep the work area dry; moisture affects readings and increases shock risk.
- Use a refrigerant leak detector to check for leaks after servicing, as electrical work may disturb piping connections.
In Tanzania, many commercial buildings and hotels in cities like Arusha and Mwanza use large air conditioning compressors above 60 kW to cool offices and guest rooms. When such a system stops cooling, a technician uses a multimeter and clamp meter to check whether the compressor is receiving the correct voltage, whether the current draw is too high, and whether the motor windings have the right resistance. This quick electrical diagnosis saves time and money by pinpointing whether the fault is electrical or mechanical before ordering replacement parts.
How you'll be assessedProcess assessment · Outcome assessment · Knowledge assessment
Process assessment
- Select tools and equipment for a task
- Performing diagnostic troubleshooting
- Performing bearing greasing
- Performing pump down
- Replace air filters
- Repair compressors
- Detect leaks
- Performing sheet metal works
- Inspect electrical components
- Carry out plumbing works
- Check/refill oil level
- Store tools and equipment
- Clean equipment and workplace
Outcome assessment
A record of service works carried out conforms to technical specifications
Knowledge assessment
Knowledge evidence:
Detailed knowledge of:
Method used: The student should explain how to:
- Assemble and disassemble according to procedures
- Apply different leakage detection methods
- Performing diagnostic trouble shooting
Principles: The student should explain the principles of:
- Heat transfer in a heat exchanger
- Compression refrigeration cycle
- Primary and secondary refrigerants
Theories: The student should explain:
- Pressure temperature charts for different refrigerants
- Super heating as it refers to refrigeration
- Application of oil and greasing lubricants
Detailed knowledge about:
- Safe handling of working tools and equipment
- Electric circuitry
- Pressure and temperature quantities with reference to refrigeration
- Safe handling of refrigerants during charging, discharging and storage
- Environmental regulations on green gases
Question
In Tanzania, what is the standard voltage for a three-phase supply used for large compressors above 60 kW?
Sign in to submit your answer and have it count toward your mastery.
Sign in to practiceTutor
Stuck? Ask me anything about this topic.
Sign in to ask the Sonza AI Tutor about this question.
Sign in to askDiscussions
No questions yet