Topics in this sectionInfrared spectroscopy1 topic
- IR spectroscopy for functional group identification
Infrared Spectroscopy for Identifying Functional Groups
Infrared (IR) spectroscopy is an analytical technique that helps chemists identify which functional groups are present in an organic compound. A functional group is a specific group of atoms within a molecule that gives the compound its characteristic chemical behavior. For example, the –OH group makes a compound an alcohol, while the –COOH group makes it a carboxylic acid.
When infrared light shines through a sample, certain bonds in the molecule absorb that light. Different types of bonds—such as O–H, C–H, C=O, and N–H—absorb IR light at characteristic frequencies. By measuring which frequencies of light are absorbed, we can tell what kinds of bonds exist in the molecule, and therefore what functional groups are present.
The instrument used is called an infrared spectrophotometer. It has four main parts:
- IR source — produces infrared light
- Sample holder — where the compound being tested is placed
- Detector — measures how much light passes through the sample
- Recorder — produces a graph called an IR spectrum
The spectrum plots the wavenumber (measured in cm⁻¹, which is the number of waves per centimeter) on the horizontal axis against the percentage of light transmitted on the vertical axis. When a bond absorbs IR light, the spectrum shows a "dip" or peak at that wavenumber. Scientists read the spectrum from right to left, starting at about 4000 cm⁻¹ down to about 400 cm⁻¹.
The IR spectrum is divided into two important regions that chemists read in different ways:
The Functional Group Region
This covers roughly 4000 cm⁻¹ to about 1500 cm⁻¹. Bonds involving hydrogen (O–H, N–H, C–H) and triple bonds (C≡C, C≡N) appear here. Because each functional group produces a peak at a characteristic wavenumber, this region tells you "what" groups are present.
For example:
- A broad peak around 3200–3600 cm⁻¹ indicates an O–H group (alcohol or carboxylic acid)
- A sharp peak around 1700 cm⁻¹ indicates a C=O group (carbonyl), found in aldehydes, ketones, carboxylic acids, and esters
- Peaks around 2850–2960 cm⁻¹ indicate C–H bonds in alkanes
This is how you identify the OH group as required by the syllabus — look for the peak near 3000 cm⁻¹.
The Fingerprint Region
This covers about 1500 cm⁻¹ down to 400 cm⁻¹. This region is called the fingerprint region because it is unique to each individual compound, much like a fingerprint identifies a person. Small differences in molecular structure—even tiny changes—produce different patterns in this region.
Chemists use the fingerprint region to confirm the identity of a compound. If two substances have the same peaks in the functional group region but different patterns in the fingerprint region, they are not the same compound.
Imagine you are given an unknown liquid that may be ethanol (C₂H₅OH) or dimethyl ether (CH₃OCH₃). Both contain carbon, hydrogen, and oxygen, but they have different functional groups.
Looking at the IR spectrum:
- If you see a broad peak around 3300 cm⁻¹, this tells you there is an O–H group (alcohol). This confirms the compound is ethanol.
- If there is no O–H peak around 3300 cm⁻¹, and you see only C–H peaks and C–O peaks in the fingerprint region, the compound is likely dimethyl ether.
This is how IR spectroscopy answers the question: "What functional groups does this molecule contain?"
- Infrared spectroscopy: An analytical method that uses infrared light to identify functional groups in organic compounds.
- Spectrophotometer: The instrument that measures how a sample absorbs or transmits IR light.
- Fingerprint region: The region of an IR spectrum from about 1500 to 400 cm⁻¹ that is unique to each compound and is used to confirm identity.
- Functional group: A specific group of atoms within a molecule that determines how the molecule behaves chemically.
In South Sudan, IR spectroscopy is used at the Nile Basin Initiative water testing laboratories in Juba to analyze water samples. When testing whether borehole water is safe for drinking, IR spectroscopy can detect organic contaminants that come from agricultural runoff or industrial waste near the Nile. The technique helps confirm the presence of harmful compounds like pesticides or petroleum residues, protecting communities from waterborne illness.
Question
What are the four main parts of an infrared spectrophotometer?
Sign in to submit your answer and have it count toward your mastery.
Sign in to practiceTutor
Stuck? Ask me anything about this topic.
Sign in to ask the Sonza AI Tutor about this question.
Sign in to askDiscussions