Topics in this sectionElectromagnetic Induction5 topics
Transformers
A transformer is a device that changes the voltage of an alternating current (AC) electricity supply. It can make the voltage bigger (step-up) or smaller (step-down). This is very important because electricity must be at high voltage to travel long distances through power lines, but it must be at low, safe voltage for use in homes and schools.
There are two main types of transformers:
Step-up transformer — This increases the voltage. It has more turns of wire in the secondary coil (the output side) than in the primary coil (the input side). If you connect 240 V to the primary, you might get 4800 V from the secondary.
Step-down transformer — This decreases the voltage. It has fewer turns in the secondary coil than in the primary coil. This is the type used to reduce mains voltage (like 240 V) to a safer level (like 12 V) for small appliances.
You can tell which type a transformer is by comparing the number of turns on each coil.
A simple transformer has three main parts:
- Primary coil — The coil connected to the input voltage (where the AC supply enters).
- Secondary coil — The coil connected to the output (where the transformed voltage comes out).
- Laminated core — A core made of soft iron that is layered (laminated) to reduce energy loss. The core carries the magnetic field from the primary coil to the secondary coil.
The coils are usually made of insulated copper wire. When they are wound close together on the core, the magnetic field from the primary easily reaches the secondary.
Transformers work through a process called mutual induction. Here is what happens:
- An alternating voltage is applied to the primary coil.
- This creates an alternating (changing) magnetic field in the primary coil.
- The soft iron core channels this changing magnetic field through the secondary coil.
- The changing magnetic field in the secondary coil induces (creates) an alternating voltage across the secondary coil.
For this to work, the input voltage must be alternating (changing). A steady direct current (DC) would not produce a changing magnetic field, and no voltage would be induced in the secondary.
For an ideal transformer (one with no energy loss), the ratio of the voltages equals the ratio of the number of turns:
VpVs=NpNs
Where:
- Vp = primary voltage (input)
- Vs = secondary voltage (output)
- Np = number of turns on the primary coil
- Ns = number of turns on the secondary coil
This means if you double the number of turns on the secondary, you double the voltage.
In an ideal transformer, the power going in equals the power coming out:
Vp×Ip=Vs×Is
Where Ip and Is are the currents in the primary and secondary coils.
This tells us an important rule: when voltage goes up, current goes down, and vice versa. A step-up transformer increases voltage but decreases current. A step-down transformer decreases voltage but increases current.
You can also write this as a ratio:
VpVs=IsIp=NpNs
In the real world, some energy is always lost in a transformer. The efficiency of a transformer is calculated as:
Efficiency=Power inputPower output×100%
Well-designed transformers can be up to 98% efficient, meaning only 2% of the power is lost. The losses happen because:
- Resistance in the coils — The wire heats up and wastes energy (Joule heating).
- Eddy currents — Small currents induced in the core heat it up. The core is laminated (made of thin sheets) to reduce this.
- Hysteresis loss — Repeated magnetising and demagnetising of the core uses energy. Soft iron is used because it is easy to magnetise and demagnetise.
- Magnetic flux leakage — Not all the magnetic field from the primary reaches the secondary. This is reduced by using a closed-loop core design.
A transformer has 200 turns on the primary coil and 4000 turns on the secondary coil. The input voltage is 240 V.
(a) What type of transformer is this? Since Ns>Np (4000 > 200), this is a step-up transformer.
(b) Calculate the output voltage.
240Vs=2004000 Vs=240×2004000=240×20=4800 V
(c) If the secondary current is 0.2 A, what is the primary current?
For an ideal transformer: Vp×Ip=Vs×Is
240×Ip=4800×0.2 Ip=240960=4 A
Notice the current dropped from 4 A to 0.2 A while the voltage rose from 240 V to 4800 V.
A school in Juba needs 12 V AC to run a small projector. The mains supply is 240 V. The primary coil has 1000 turns. How many turns should the secondary coil have?
VpVs=NpNs 24012=1000Ns Ns=24012×1000=50 turns
So the secondary coil needs 50 turns.
A transformer has 60 turns on the primary and 1200 turns on the secondary. The input voltage is 240 V and the output power is 3600 W. If the efficiency is 80%, find:
(a) Output voltage
240Vs=601200 Vs=240×601200=240×20=4800 V
(b) Output current
P=V×I 3600=4800×Is Is=48003600=0.75 A
(c) Input current
Efficiency = (Power output ÷ Power input) × 100%
0.80=Pin3600 Pin=0.803600=4500 W
Now find input current: 4500=240×Ip Ip=2404500=18.75 A
Transformers are essential in our electricity system:
-
Power transmission — Electricity travels from the dam or power station to your town at very high voltage (like 11,000 V or more). This reduces the current, which reduces energy lost as heat in the power lines. A transformer at the power station steps the voltage up, and another transformer near your town steps it down to 240 V for home use.
-
Battery charging — Phone chargers and laptop adapters contain small step-down transformers to reduce mains voltage to a safe level for charging.
-
Welding — Special transformers step up the current (not the voltage) to produce the very high currents needed to melt metal for welding.
In towns like Juba, Wau, and Malakal, the electricity supplied to homes is usually 240 V AC from the national grid. When you charge a phone or use a radio, a small step-down transformer inside the charger or device reduces this 240 V to a much lower voltage (like 5 V or 12 V) that the device can safely use. If you walk near a large power transformer in an industrial area, you may hear a humming sound — this is the transformer working as it changes the voltage for distribution to different parts of the city.
Question
A transformer has 200 turns on the primary coil and 4000 turns on the secondary coil. What type of transformer is this?
Sign in to submit your answer and have it count toward your mastery.
Sign in to practiceTutor
Stuck? Ask me anything about this topic.
Sign in to ask the Sonza AI Tutor about this question.