Mada za sehemu hiiInstalling cablesMada 4
- Installing PVC cables
- Installing paper insulated cables
- Installing armoured cables
- Performing underground wiring systems
Armoured cables are electrical cables that include an additional protective layer made of steel or aluminium wire or tape, providing extra mechanical protection to the insulation. This makes them suitable for harsh environments where cables might be exposed to physical damage, moisture, or underground conditions.
Armoured cables consist of several layers that work together to protect the conductors inside. Understanding each component is essential for proper selection and installation.
Components of an Armoured Cable
-
Conductors: The innermost part that carries electric current. Conductors are typically made from copper or aluminium because these materials have low electrical resistance.
-
Insulation: A layer of material (such as PVC or XLPE) that surrounds each conductor, preventing current from leaking and ensuring safe delivery of electrical energy.
-
Bedding (Inner Sheath): A protective layer placed over the insulation, usually made of rubber or PVC. It shields the cable from moisture, gases, and harmful liquids that could damage the insulation.
-
Armouring: The key feature of armoured cables. This is a layer of steel wires, steel tapes, or aluminium wires that provides mechanical protection against damage during installation and handling.
-
Outer Sheath: The final protective layer that covers the armouring and protects it from atmospheric conditions like sunlight, rain, and chemicals.
Armoured cables are classified based on the material and form of their protective layer:
-
Steel Wire Armoured Cable (SWA): The armour is made from steel wires. This type offers high tensile strength and is commonly used for underground installations.
-
Steel Tape Armoured Cable (STA): The armour consists of wound steel tapes. It provides good protection against crushing and is suitable for direct burial where high tensile strength is not required.
-
Aluminium Wire Armoured Cable (AWA): The armour is made from aluminium wires. This type is primarily used for single-core cables because aluminium is non-magnetic and prevents overheating issues that would occur with steel armour in single-phase applications.
Advantages
- High mechanical strength: The armour layer protects cables from physical damage during installation and in harsh environments.
- Increased lifespan: Better protection means cables last longer with reduced maintenance needs.
- Resistance to harsh environments: Suitable for underground, outdoor, and industrial applications.
- Good for direct burial: Can be laid directly in the ground without additional protection.
Disadvantages
- More expensive: The additional protective layers increase production costs compared to unarmoured cables.
- Less flexible: The armour makes the cable stiffer and harder to bend, making installation more challenging.
- Heavier: The steel or aluminium components add weight to the cable.
Armoured cables are used in environments where cables are likely to be exposed to mechanical damage:
- Construction sites
- Industrial settings and factories
- Underground or outdoor installations
- Areas with high moisture or chemical exposure
- Mining and petrochemical plants
When working with armoured cables, proper technique is essential to avoid damaging the conductor or insulation.
Steps for Measuring and Cutting
- Measure the required length using a measuring tape, allowing for any bends and termination requirements.
- Mark the cutting point clearly on the outer sheath.
- Secure the cable using a bench vise or cable holder to prevent movement during cutting.
- Cut through the outer sheath using diagonal cutting pliers or a hacksaw, being careful not to damage the armour layer underneath.
- Remove the outer sheath by cutting it lengthwise and peeling it back.
Steps for Stripping the Armour
- Expose the armour layer by removing the outer sheath at the stripping point.
- Mark the point where the armour will be cut, ensuring enough length for proper termination.
- Cut the armour using appropriate tools:
- For steel wire armour, use wire cutters or diagonal pliers
- For steel tape armour, use a knife or cable stripper
- Remove the armour carefully without damaging the inner sheath (bedding) or the conductors inside.
- Strip the inner sheath (bedding) to expose the individual conductors, using a knife or cable stripper.
- Strip the conductor insulation to expose the bare conductor for termination, using wire strippers appropriate for the conductor size.
Safety Precautions
- Always wear appropriate PPE: leather gloves, safety goggles, safety boots, and overalls.
- Ensure the power supply is switched off and locked out before working on any cable.
- Use the correct tools for each step to avoid damaging the cable.
- Follow the manufacturer's instructions for specific cable types.
Example: A construction site in Dar es Salaam requires an armoured cable to run 50 metres underground from the main distribution board to a temporary site office. The load will be approximately 15 amperes.
Solution: For this application:
- Choose a steel wire armoured cable (SWA) because it provides excellent mechanical protection for underground installation.
- Select an appropriate size. For a 15A load at 230V, a 2.5mm² cable would typically be suitable, but considering voltage drop over the 50m distance and the need for extra protection in harsh environments, a 4mm² cable is recommended.
- The armoured construction protects the cable from moisture and physical damage from soil pressure and any accidental digging.
In Tanzania, armoured cables are commonly used for wiring borehole water pumps in rural villages such as those in Singida or Shinyanga regions. These pumps are often located outdoors or underground, and the armoured cable protects the wiring from moisture, soil pressure, and accidental damage from digging activities. A properly installed armoured cable ensures the pump operates reliably throughout the year, providing clean water to the community without frequent maintenance costs.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
The students should be able to explain how to explain how:
- Select tools, equipment and safety gear
- Interpret wiring drawings
- Select area for armoured cables installation
- Install armoured cables
- Terminate cable
- Observe safety precaution
- Clean work area.
- Store tools, equipment’s and safety gear.
Tathmini ya matokeo
An armoured cable is installed as per IET regulations.
Tathmini ya maarifa
Knowledge evidence: Detailed knowledge of:
Methods used: The students should explain how to install armoured cables Principle: Students should be able to demonstrate the correct procedures for installing armoured cables
Theories: The students should explain
- Armoured cables
- Steps to consider for armoured cables
- IET regulations
Swali
Which layer of an armoured cable provides the main mechanical protection against physical damage during installation and handling?
Ingia ili kuwasilisha jibu lako na lihesabiwe katika umahiri wako.
Ingia ili kufanya mazoeziMwalimu
Umekwama? Niulize chochote kuhusu mada hii.
Ingia ili kumuuliza Mwalimu wa AI wa Sonza kuhusu swali hili.
Ingia ili kuulizaMajadiliano
Hakuna maswali bado