Topics in this sectionCathode Ray Tube4 topics
- Production of cathode rays
- Properties of cathode rays
- Cathode ray oscilloscope (C.R.O.)
- Uses of cathode ray oscilloscope
The Cathode Ray Oscilloscope
A cathode ray oscilloscope, often called a CRO, is a scientific instrument that displays electrical signals as visual waveforms on a screen. It works by using a beam of electrons that can be deflected by electric fields. The CRO is like a "visual voltmeter" — instead of just reading a number, you can actually see how a voltage changes with time.
A CRO is made up of several important parts that work together to produce a visible waveform.
The Electron Gun
The electron gun is the part that produces the beam of electrons. It contains a heated filament that releases electrons, a control grid that regulates how many electrons are emitted (this controls the brightness of the spot on the screen), and accelerating plates that speed up the electrons into a narrow beam. The focus control adjusts the beam so that it stays narrow and produces a sharp dot on the screen.
The Screen
The screen is coated with a special material called phosphor. When the electron beam strikes the phosphor, it glows briefly, producing a bright spot. This spot shows where the electron beam is hitting the screen at any moment.
The Deflection Plates
There are two pairs of metal plates inside the CRO:
- Y-plates (vertical deflection plates) are connected to the input signal you want to study. When a voltage is applied to these plates, the electron beam is pushed up or down, creating vertical movement on the screen.
- X-plates (horizontal deflection plates) are connected to the time-base circuit. These plates move the electron beam from left to right across the screen at a steady rate.
Two important controls allow you to adjust what you see on the screen.
Y-Gain (Vertical Sensitivity)
The Y-gain control adjusts how much the electron beam moves up or down for a given input voltage. It is measured in volts per centimetre (V/cm). If the Y-gain is set to 5 V/cm and the beam moves up 4 cm, then the input voltage is:
Voltage=5V/cm×4cm=20V
A higher Y-gain setting makes the waveform appear taller, while a lower setting makes it smaller.
Time-Base (Horizontal Sweep)
The time-base applies a special "saw-tooth" voltage to the X-plates. This voltage rises steadily, pulling the electron beam from the left side of the screen to the right side. Then it quickly drops back to the left and starts again. This pulling action is called the flyback mechanism.
The time-base is measured in seconds per centimetre (s/cm) or milliseconds per centimetre (ms/cm). If the time-base is set to 1 ms/cm, the electron beam takes 1 millisecond to move 1 cm across the screen.
DC Voltage on the Y-Plates
When a steady DC voltage is applied to the Y-plates with the time-base turned on, you see a horizontal line that is shifted up or down. If the positive terminal connects to the lower plate, the line moves upward. Reversing the connections moves the line downward.
AC Voltage on the Y-Plates
When an alternating (ac) voltage is applied to the Y-plates, the electron beam moves up and down repeatedly. Combined with the time-base sweeping horizontally, this produces a sine wave shape on the screen. The height of the wave shows the amplitude (peak value) of the voltage, and the number of complete waves visible shows the frequency.
A student connects a DC voltage to a CRO. The Y-gain is set to 10 V/cm, and the spot deflects upward by 2 cm on the screen.
What is the input voltage?
Using the formula:
Voltage=Y−gain×deflection
Voltage=10V/cm×2cm=20V
The input DC voltage is 20 volts.
The CRO is a versatile instrument used in many ways:
- Measuring voltage amplitudes — The CRO can measure both DC and AC voltages accurately. Because it takes no current from the circuit being measured, it has very high resistance, like an ideal voltmeter.
- Measuring frequency — By adjusting the time-base until the waveform appears stationary, you can count how many complete waves fit in a certain distance on the screen. From this, you calculate the time period and then the frequency using: f=T1
- Measuring small time intervals — The CRO can measure very short time differences between two signals, such as the time between two sound pulses picked up by a microphone.
In South Sudan, a cathode ray oscilloscope can be found in the electronics workshop at the University of Juba or in hospitals where it is used with ECG machines to monitor heart activity. When a doctor checks a patient's heartbeat, the electrical signals from the heart are displayed as a waveform on a screen — this is the same principle of the CRO translating electrical signals into visual patterns. Technicians repairing radio equipment in markets in Wau or Malakal also use oscilloscopes to check whether audio signals are working properly in damaged receivers.