Topics in this sectionCathode Ray Tube4 topics
- Production of cathode rays
- Properties of cathode rays
- Cathode ray oscilloscope (C.R.O.)
- Uses of cathode ray oscilloscope
Using the Cathode Ray Oscilloscope to Measure Voltage, Frequency, and Time
The cathode ray oscilloscope (CRO) is a valuable instrument that can display electrical signals as waveforms on a fluorescent screen. Beyond just showing the shape of a signal, the CRO allows us to measure three important quantities: voltage, frequency, and time intervals. This makes it useful in many practical situations, from checking electrical equipment to timing events in sports.
When you connect a voltage to the Y-input of a CRO, the electron beam is deflected vertically. The amount of deflection depends on two things: the size of the voltage and the setting of the Y-gain (also called volt-per-centimetre gain).
The Y-gain control tells you how many volts cause 1 centimetre of vertical deflection on the screen. For example, if the Y-gain is set at 5 V/cm, then a voltage of 5 volts will move the trace 1 centimetre up or down from the centre line.
To measure a DC voltage, you observe how far the spot or trace shifts from the zero position. The voltage is calculated as:
Voltage = vertical deflection (cm) × Y-gain (V/cm)
For an AC voltage, you measure the peak value — the distance from the centre line to the highest point of the waveform — and multiply by the Y-gain setting.
The CRO has a built-in circuit called the time-base that sweeps the electron beam horizontally across the screen at a regular speed. This creates the horizontal axis of the display, representing time.
The time-base setting tells you how much time each centimetre represents on the horizontal axis. For example:
- A time-base of 10 ms/cm means each centimetre represents 10 milliseconds (0.01 seconds)
- A time-base of 50 ms/cm means each centimetre represents 50 milliseconds (0.05 seconds)
To measure the frequency of a signal, you first measure the time period (T) — the horizontal distance for one complete wave (from one peak to the next peak). Then:
Frequency (f) = 1 / Time period (T)
If the wavelength (the distance for one complete cycle) is 1 cm and the time-base is 10 ms/cm, then the time period is 10 ms = 0.01 s, and the frequency is 1/0.01 = 100 Hz.
Imagine two athletes finish a race very close together, and a CRO with a time-base of 50 ms/cm is used to measure the time difference between them. The screen shows two pulses, and the distance between the pulses is measured as 2 cm.
To find the time interval:
- Distance between pulses = 2 cm
- Time-base = 50 ms/cm = 0.05 s/cm
- Time interval = 2 cm × 0.05 s/cm = 0.10 s
So the time difference between the two athletes is 0.10 seconds (one-tenth of a second).
Suppose the Y-gain is set to 5 V/cm and the waveform displayed has an amplitude (peak height) of 2 cm on the vertical axis. To find the peak voltage:
- Amplitude = 2 cm
- Y-gain = 5 V/cm
- Peak voltage = 2 cm × 5 V/cm = 10 V
The peak value of this AC voltage is 10 volts. If you need the RMS value (the effective value used in most electrical calculations), you divide the peak value by √2:
RMS voltage = Peak voltage ÷ √2 = 10 ÷ 1.414 ≈ 7.07 V
- Waveform: The shape of the signal displayed on the CRO screen
- Peak value: The maximum voltage shown by the highest point of the waveform
- RMS (Root Mean Square): The effective value of an AC voltage; about 0.707 times the peak value
- Time-base: The control that sets the horizontal time scale on the CRO
- Y-gain: The control that sets the vertical voltage scale on the CRO
- Time period (T): The time for one complete cycle of a waveform
- Frequency (f): The number of cycles per second, measured in hertz (Hz)
To measure voltage:
- Set the Y-gain to a convenient value
- Connect the signal and observe the vertical deflection
- Multiply the deflection by the Y-gain setting
To measure frequency or time interval:
- Set the time-base to a convenient value
- Measure the horizontal distance for one complete wave (wavelength)
- Multiply by the time-base to get the time period
- Calculate frequency as 1 divided by the time period
In South Sudan, a CRO can be found in electronics repair workshops in Juba and Wau, where technicians use it to test car alternators and battery charging systems. When a mechanic connects the CRO to check if an alternator is producing the correct voltage, the CRO displays the waveform showing whether the output is steady (DC) or varying (AC). The time-base feature is also useful in school physics laboratories at County Secondary Schools in Malakal and other areas, where students can measure the frequency of sound signals from a tuning fork or the time interval between two claps to estimate the distance to a nearby wall, similar to how echo-sounding works on the Nile.
Question
What quantity does the Y-gain control on a cathode ray oscilloscope indicate?
Sign in to submit your answer and have it count toward your mastery.
Sign in to practiceTutor
Stuck? Ask me anything about this topic.
Sign in to ask the Sonza AI Tutor about this question.
Sign in to askDiscussions
No questions yet