Mada za sehemu hiiInstalling lighting circuitsMada 4
- Installing lighting points controlled by one way one gang switch
- Installing lighting points controlled by one, two, and three-way gang switches
- Installing lighting points controlled by two two-way switches
- Installing lighting points controlled by two-two-way switches and an intermediate switch
A gang is one switch mounted on a faceplate. A faceplate that carries two or three switches is called a two-gang or three-gang switch. A switch unit can have:
- One gang – controls one light from one position
- Two gangs – controls two separate lights (each gang operates independently)
- Three gangs – controls three separate lights from one position
Switches are also described by how many positions control them:
- One-way switch – light can only be turned ON or OFF from one switch position
- Two-way switch – light can be controlled from two different switch positions
- Three-way switch – light can be controlled from three different switch positions (uses an intermediate switch)
A one-way two-gang switch has two independent one-way switches on a single faceplate. Each gang controls its own lighting circuit.
Terminal arrangement
A one-way switch has two terminals (Live and Switched Live).
- COM (Common) – connects to the live supply
- L1 – connects to the switched live (line) going to the lamp
Wiring description
For a one-way two-gang switch:
- The live conductor (L) from the distribution board is connected to the COM terminal of each gang. A short link of the same size of cable joins one COM terminal to the next.
- A switched live conductor runs from L1 of each gang to its respective lamp holder.
- The neutral (N) and earth (E) conductors run directly to each lamp holder without passing through the switch.
- Each gang operates completely independently of the other.
A one-way three-gang switch is wired in the same way, with the live linked to three COM terminals and three switched live conductors, one to each of three lamps.
When it is used
- In a bedroom with two ceiling lamps, each gang controls one lamp separately.
- In a hallway where two different lights need independent on/off control from the same wall position.
A two-way switch allows a lamp to be controlled from two different positions. A two-gang two-way switch has two independent two-way switches on one faceplate.
Terminal arrangement
A two-way switch has three terminals:
- COM (Common) – connects to the live supply (input)
- L1 – first switching position
- L2 – second switching position
How two-way switching works
Each switch connects its COM terminal to either L1 or L2. The lamp is ON when both switches are connected to the same linking wire (called a strapper), because the path from the live supply to the lamp is then complete. Operating either switch moves it to the other strapper and breaks the path, so the lamp can be turned ON or OFF from either switch location.
Wiring description for two-way circuit
- Connect the live supply (L) from the DB to the COM terminal of the first two-way switch.
- Run one conductor (a strapper) between L1 of switch 1 and L1 of switch 2.
- Run a second strapper between L2 of switch 1 and L2 of switch 2.
- Connect the COM terminal of the second two-way switch to the lamp holder.
- Run neutral (N) and earth (E) conductors directly to the lamp holder.
When it is used
- Staircase lighting: one switch at the bottom of the stairs and one at the top.
- Long corridor: switches at both ends of the corridor.
- A room with two doors: a switch beside each door controlling the same light.
Two-gang two-way combination
Each gang operates as an independent two-way circuit. Gang 1 controls Lamp 1 from two positions. Gang 2 controls Lamp 2 from two different positions (which could be the same two positions or different ones).
A three-way switching circuit controls a lamp from three different positions. This requires two two-way switches and one intermediate switch placed between them.
Terminal arrangement of intermediate switch
An intermediate switch has four terminals – two input and two output – arranged in two pairs.
Wiring description for three-way circuit
- Connect the live supply to COM of the first two-way switch.
- Run a three-core cable (or two separate conductors) from L1 and L2 of the first two-way switch to the two input terminals of the intermediate switch.
- From the two output terminals of the intermediate switch, run conductors to L1 and L2 of the second two-way switch.
- Connect COM of the second two-way switch to the lamp holder.
- Connect neutral and earth directly to the lamp holder.
How it works
The intermediate switch simply swaps the connections between the two pairs of conductors. This changes which path the current takes, effectively toggling the state of the lamp regardless of the two-way switch positions.
When it is used
- Large rooms with three entrance doors, where any door can turn the light on or off.
- Long corridors with a switch at each end and one in the middle.
- Conference halls or classrooms with multiple entry points.
Follow these steps when installing any lighting circuit with gang switches:
- Plan the circuit – draw a wiring diagram showing all switches, lamp holders, and cable routes before starting.
- Isolate the supply – switch off and lock off the mains supply at the distribution board.
- Prove dead – use a voltage tester to confirm the circuit is not live. Check the tester on a known supply or proving unit before and after the test.
- Fix switch boxes and lamp holders – mount switch boxes at the required heights (commonly about 1.2 m to 1.4 m above the finished floor, or as shown on the drawing) and fix lamp holders in their positions.
- Run cables – lay cables from the DB to each switch position and from switches to lamp holders. Use appropriate cable sizes (1.5 mm² for lighting circuits).
- Make connections at switches – strip conductors carefully and connect them to the correct terminals (COM, L1, L2) according to the circuit type.
- Connect lamp holders – connect switched live to the lamp holder live terminal, neutral to neutral, and earth to earth.
- Insulate all bare conductors – cover bare earth conductors with green-and-yellow sleeving and ensure no exposed copper shows outside any terminal. Fit all switch plates and covers.
- Test, then restore the supply – with the supply still off, use the multimeter on the resistance range to check the continuity of the earth conductor and of each switched live, and that there is no connection between live and neutral (lamps removed) or between live and earth. Only when these tests are correct and the work has been checked by your instructor, fit the lamps, switch on the supply and test each switch position to confirm correct operation.
- Record results – note any observations during testing.
- Clean and store – sweep up cable offcuts and insulation strippings, wipe the tools, and return the tools, the multimeter and the unused cable and accessories to the store.
- Always isolate, lock off and prove dead before working on any circuit. Never work on a live circuit.
- Wear safety boots, overalls, and gloves during installation.
- Use tools with insulated handles.
- Do not overload circuits beyond their current rating. A lighting circuit in 1.5 mm² cable is normally protected by a 6 A circuit breaker or a 5 A fuse.
- Ensure all earth connections are properly made.
- Test your work with a multimeter before energising.
Prepare a layout drawing (the positions of switches and lamps on the plan of the room) and a wiring diagram (each conductor and its terminal) before you start. Common symbols:
| Item | Symbol |
|---|---|
| Lamp | A circle with a cross inside |
| One-way switch | A small circle with a short sloping line ending in one tick |
| Two-gang or three-gang switch | The one-way symbol drawn two or three times side by side, or with the number of gangs written beside it |
| Two-way switch | A small circle with two sloping lines pointing in opposite directions, each ending in a tick |
| Intermediate switch | A small circle with two crossed lines through it |
| Earth | A vertical line ending in three short horizontal lines, each shorter than the one above |
Temperature and conductors: the resistance of a copper conductor rises by about 0.4% for each degree Celsius, and current heats a cable. A cable that is too small, tightly bunched or covered by thermal insulation runs hot, and PVC insulation is damaged above about 70 °C. For this reason the cable size and the rating of the fuse or circuit breaker must match the load.
Wiring regulations: installation work follows the IEE Wiring Regulations and the rules of the electricity supplier. The main requirements for these circuits are:
- Single-pole switches are connected in the live (line) conductor only, never in the neutral
- Every circuit is protected by a fuse or circuit breaker of the correct rating
- An earth (circuit protective) conductor is run to every lighting point and switch position
- The installation is inspected and tested before it is put into service
Task: Draw and describe the wiring for a one-way two-gang switch controlling two lamps in a small room.
Solution:
Diagram description:
Distribution Board
|
Live (L) ----+-------- COM of Gang 1
| |
| +-------- COM of Gang 2
Neutral (N)-------------------+------- Neutral of Lamp 1
| |------- Neutral of Lamp 2
Earth (E)---------------------+------- Earth of both lamps
Gang 1:
COM --- L1 (to Lamp 1 live terminal)
Gang 2:
COM --- L1 (to Lamp 2 live terminal)
Explanation:
- The live conductor from the DB connects to the COM terminal of Gang 1, and a short link carries it on to the COM terminal of Gang 2.
- From L1 of each gang, a switched live conductor runs to its respective lamp holder.
- Neutral and earth run directly from the DB to both lamp holders.
- Each lamp can be switched on or off independently using its own gang switch.
- This arrangement is common in a Tanzanian home where one switch plate at the door controls the main room light and a secondary lamp separately.
In a Tanzanian household, a two-gang switch at the main door of a sitting room allows the family to control two lights independently from one position — one gang for the main ceiling bulb and one for a wall lamp. When installing wiring for a new house in a village, an electrician uses two-way switching so that a light at the top and bottom of a staircase can be turned on or off from either position, which is practical for multi-storey homes and avoids the danger of walking on dark stairs.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
The student should be able to:
- Prepare electrical drawings.
- Identify tools, equipment, and required materials.
- Prepare accessories and cables for lighting circuits.
- Install lighting circuit.
- Test the installation.
- Apply safety measures.
- Clean work area.
- Store tools, equipment and remained materials.
Tathmini ya matokeo
Lighting circuits controlled by a one-way switch, two, three-gangs installed as per standards.
Tathmini ya maarifa
Knowledge evidence:
Detailed knowledge of:
Method used: The student should explain how to install lighting points controlled by one, two, and three-way gang switches.
Principles: The student should explain the principles of Installing lighting points controlled by one, two, and three-way gang switches.
Theories: The student should explain:
- Electrical symbols used in wiring diagram.
- Tools and equipment used in wiring circuits.
- Effect of temperature in conducting materials.
Circumstantial knowledge:
Detailed knowledge about:
- Safety precautions.
- IEE regulations.
Swali
How many terminals does a single one-way switch (one gang) have?
Ingia ili kuwasilisha jibu lako na lihesabiwe katika umahiri wako.
Ingia ili kufanya mazoeziMwalimu
Umekwama? Niulize chochote kuhusu mada hii.
Ingia ili kumuuliza Mwalimu wa AI wa Sonza kuhusu swali hili.
Ingia ili kuulizaMajadiliano
Hakuna maswali bado