Testing Milking Machines
Testing a milking machine involves checking its key systems to ensure it extracts milk efficiently, gently, and hygienically. Regular testing prevents equipment failures, protects cow udder health, and maintains milk quality. Tests are carried out daily, routinely, and periodically using both visual checks and specialized instruments.
Why Testing is Important
A properly tested milking machine:
- Ensures consistent milk yield and quality
- Prevents udder damage and mastitis
- Reduces energy waste and equipment wear
- Identifies problems before they become costly repairs
Daily Checks
These simple checks are performed before each milking session:
- Listen for leaks – Walk around the machine and listen for hissing sounds that indicate air leaks
- Inspect pipelines and interceptor tanks – Check for milk or water buildup; drain and flush if found
- Check behind liners – Look for water accumulation and drain if present
- Clear air admission hole – Ensure the small hole in the claw is not blocked with milk residues or debris
- Check vacuum pump oil – Top up if the oil level is low (oil should be at the recommended mark)
Vacuum System Test
The vacuum system creates the suction that extracts milk. Testing ensures stable pressure throughout milking.
Procedure:
- Connect a vacuum gauge to the system
- Measure the claw vacuum during milking
- Verify the vacuum remains stable during both low and peak milk flow periods
- Check the vacuum regulator if recovery is slow or if vacuum levels are too high or too low
Recommended vacuum level: 38–42 kPa (or as specified in the service manual)
Pulsation System Test
The pulsator controls the milking and massage phases of the teat cup liners. Proper pulsation ensures efficient milking without udder damage.
Procedure:
- Use a pulsator tester or analyser to check the pulsator function
- Verify the pulsation rate is within the manufacturer's recommended range, typically 40–80 pulsations per minute
- Check the milking-to-massage ratio (standard is approximately 60:40)
- Perform a wet test or listen to the pulsators to confirm they are operating correctly
- Ensure air admission holes in the claw are clear
Airflow Test
Adequate airflow is needed to maintain vacuum stability and proper milk transport.
Procedure:
- Use an airflow meter to measure airflow through the machine
- Check all vacuum-operated components for leaks
- Inspect hoses and connections for cracks or disconnections
Visual Inspection
A thorough visual inspection checks for physical wear and damage:
- Examine all hoses, pulsators, and teat cup liners for cracks, wear, or damage
- Verify liners fit correctly onto the claw nipples
- Check that teat cups are aligned vertically under the udder
- Ensure hoses are not twisted or kinked
- Inspect the cluster alignment – the claw outlet should point between the cow's legs
After Test Actions
After completing all tests, compile a report that includes:
- A list of all components tested
- Pass or fail status for each component
- Specific recommendations for repairs or adjustments
- Any deficiencies identified during testing
Any issues found must be addressed immediately to ensure the machine operates at full capacity.
Real-life application
A small-scale dairy farmer in Morogoro uses a two-unit milking machine to milk five cows twice daily. After noticing a drop in milk yield and some cows showing signs of teat damage, the farmer tests the machine using a vacuum gauge and pulsator tester. The test reveals low vacuum pressure (below 38 kPa) and a blocked air admission hole in the claw. After cleaning the blockage and adjusting the vacuum regulator, milk flow returns to normal and teat health improves, preventing potential mastitis and maintaining the farm's milk production and income.