Mada za sehemu hiiUsing of oscilloscopeMada 3
- Displaying low frequency signal
- Displaying high frequency signal
- Measuring voltage, current and frequency
A low-frequency signal is an electrical waveform that repeats slowly, typically at frequencies below the range of human hearing (below about 20 Hz). In electronics repair, we need to display these signals to check whether circuits are working correctly and to find faults.
A low-frequency signal changes direction slowly over time. Examples include:
- Power supply outputs (50 Hz or 60 Hz from the mains)
- Slow-changing sensor outputs
- Audio sub-bass signals
These signals appear as waves on an oscilloscope screen, allowing technicians to see their shape, amplitude, and period.
The main tools are:
- Oscilloscope – displays the waveform as a graph of voltage versus time
- Signal generator – produces test signals of known frequency and amplitude
- Probe – connects the oscilloscope to the circuit under test
Before starting, put on safety gear: gloves, overcoat or overall, and boots to protect against electrical shock.
Follow these steps:
- Turn on the oscilloscope and let it warm up for a minute.
- Connect the ground (black) clip of the oscilloscope probe to the ground of the circuit or signal generator.
- Connect the signal (red) clip of the probe to the output of the signal generator or the test point in the circuit.
- Set the signal generator to produce a low-frequency output (for example, 2 Hz sine wave).
To see the signal clearly, adjust these three main controls:
1. Time Base (Horizontal Scale)
The time base control sets how much time each division on the horizontal axis represents. For a 2 Hz signal, use a time base of about 100 ms/div or 200 ms/div so you can see several complete cycles on the screen.
2. Voltage Scale (Vertical Scale)
The voltage scale control sets how many volts each vertical division represents. Adjust it so the waveform fills about half the screen vertically without going off the edges. Start with 1 V/div and change as needed.
3. Trigger Controls
The trigger control stabilizes the waveform on the screen. Set the trigger level to the middle of the signal's amplitude and select the appropriate trigger source (usually CH1). Adjust the trigger slope to match the signal.
A student sets a signal generator to produce a 5 Hz sine wave with an amplitude of 2 V peak-to-peak. The student connects the oscilloscope probe and observes the display.
Step 1: Set time base to 50 ms/div. At 5 Hz, one cycle takes 200 ms. With 10 divisions across the screen, 50 ms/div shows one full cycle clearly.
Step 2: Set voltage scale to 500 mV/div. A 2 V peak-to-peak signal is 1 V from center to peak. At 500 mV/div, the waveform will be about 2 divisions high, fitting well on the screen.
Step 3: Adjust the trigger level to about 0 V (center of the waveform) and select trigger slope "+" to lock the waveform in place.
The student now sees a stable, clear sine wave on the oscilloscope screen.
- Always start with a higher time base (slower sweep) and adjust finer.
- If the waveform jumps or slides across the screen, adjust the trigger level.
- Keep probe compensation calibrated for accurate measurements.
- Ensure good grounding to avoid noisy or distorted waveforms.
- Keep the workbench dry and tidy.
- Do not touch live circuits while the oscilloscope is connected.
- Use insulated tools and wear protective gear at all times.
In Tanzania, electronics technicians use oscilloscopes to repair television sets and radio receivers found in many homes in Dar es Salaam and other towns. When a customer brings a TV that shows no picture, the technician can check the power supply's low-frequency output (50 Hz from the mains) on the oscilloscope to confirm whether the voltage is correct, helping to quickly identify faulty components and reduce repair costs.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
- Select tools and equipment
- Use oscilloscope
- Calibrate oscilloscope
- Observe safety regulations
- Clean tools and equipment
- Store tools and equipment
Tathmini ya matokeo
Oscilloscope displays measured quantities as per technical specifications.
Tathmini ya maarifa
Knowledge evidence:
Detailed knowledge of:
Method used: The student should explain how to use oscilloscope
Principles: The student should explain the principles of:
- Setting oscilloscope
- Measuring electrical quantities using oscilloscope
Theories: The student should explain:
- Parts of oscilloscope
- Application of oscilloscope
Circumstantial knowledge:
Detailed knowledge about:
- Safety precautions while using oscilloscopes
- Safe handling of test equipment
Swali
What is the typical frequency range of a low-frequency signal as described in the lesson?
Ingia ili kuwasilisha jibu lako na lihesabiwe katika umahiri wako.
Ingia ili kufanya mazoeziMwalimu
Umekwama? Niulize chochote kuhusu mada hii.
Ingia ili kumuuliza Mwalimu wa AI wa Sonza kuhusu swali hili.
Ingia ili kuulizaMajadiliano
Hakuna maswali bado