Mada za sehemu hiiInstalling control of DC machinesMada 3
- Installing diverter resistor to the armature
- Installing varistor in the field winding
- Installing autotransformer starter
A diverter resistor is a component added to the armature circuit of a DC motor to limit the high starting current that flows when the motor is first switched on. When a DC motor starts, the armature is stationary, so the back EMF is zero. This causes the starting current to be much higher than the normal running current, which can damage the windings or cause the supply to overload. The diverter resistor is placed in parallel (shunt) with the armature to provide an alternate path for some of the current, reducing the flow through the armature windings during startup.
A resistor is an electrical component that opposes the flow of current. When placed in a circuit, it converts electrical energy into heat. The relationship between voltage (V), current (I), and resistance (R) is given by Ohm's Law:
V=I×R
This means that by increasing the resistance in a circuit, we can decrease the current flowing through it. In DC motor control, resistors are used to limit current and protect sensitive components.
When a DC motor is started, the armature has not yet begun to rotate, so there is no counter-electromotive force (CEMF) to oppose the applied voltage. Without protection, the initial current can be 5 to 10 times higher than the normal running current. A diverter resistor is connected in parallel with the armature winding. During startup:
- The diverter resistor provides an additional path for current
- Current divides between the armature and the diverter resistor
- Less current flows through the armature windings
- This protects the windings from damage due to high starting current
As the motor speeds up, the back EMF increases, and the current naturally decreases. The diverter resistor may then be bypassed or reduced.
In a typical DC motor circuit with a diverter resistor:
- The supply voltage is applied across the armature and the diverter resistor in parallel
- The armature and diverter resistor share the same voltage
- Current from the supply splits: some flows through the armature, some through the diverter resistor
- The resistance of the diverter is chosen to divert enough current to protect the armature while allowing enough current for starting torque
Follow these steps to install a diverter resistor to the armature:
Step 1: Safety First
- Wear safety goggles, safety boots, leather gloves, and overalls
- Ensure the work area is clean and free of moisture
- Disconnect the power supply before starting any work
Step 2: Prepare the Tools
Gather the required tools:
- Rawl plug and hammer
- Screwdrivers (set)
- Ball pein hammer and cross pein hammer
- Megger (for insulation testing)
- Diagonal cutting pliers
- Combination pliers
- Electrician knife
- Multimeter
Step 3: Inspect the Armature and Circuit
- Examine the armature windings for any visible damage
- Use the megger to test insulation resistance between the armature windings and the motor frame
- Ensure the resistance is within acceptable limits (typically above 1 MΩ)
Step 4: Position the Diverter Resistor
- Mount the diverter resistor securely near the motor terminal box
- Use appropriate fasteners (rawl plugs and screws) to fix the resistor in place
Step 5: Connect the Wiring
- Identify the armature terminals (usually marked A1 and A2)
- Connect one end of the diverter resistor to terminal A1
- Connect the other end to terminal A2, creating a parallel connection
- Use proper crimping or soldering as required
- Secure all connections with terminal nuts and washers
Step 6: Verify the Connections
- Use the multimeter to check continuity of the circuit
- Ensure there are no short circuits between the resistor and the motor frame
- Verify that the parallel connection is correct
Step 7: Test the Installation
- Reconnect the power supply
- Start the motor and observe the startup behavior
- Check that the motor starts smoothly without excessive current draw
- Monitor for any abnormal heating or vibrations
If a DC motor requires a starting current limit from 50 A to 20 A, and the supply voltage is 240 V, what should be the resistance of the diverter resistor?
Using Ohm's Law for the parallel circuit:
Rdiverter=IdiverterV
The current through the diverter must be:
Idiverter=50A−20A=30A
Therefore:
Rdiverter=30A240V=8Ω
A diverter resistor of approximately 8 ohms would limit the armature current to 20 A during startup.
In Tanzania, small-scale solar power systems often use DC motors for water pumping in farms and villages. When installing these pumps, technicians apply knowledge of diverter resistors to protect the motor windings from damage caused by high starting currents, especially in areas where the solar panel voltage may fluctuate. A technician at a fish farm in Mwanza using a DC-powered water pump would need to correctly install the diverter resistor to ensure the pump starts safely each morning when the sun rises, preventing costly motor replacements and ensuring reliable water supply for the fish ponds.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
The students should be able to explain how to:
- Interpret wiring diagrams.
- Install diverter resistor to armature circuit.
- Terminate cables to D.C. machine control systems.
- Test the D.C. machine control.
- Observe safety precautions.
- Clean the work place.
- Store tools, equipment and safety gear.
Tathmini ya matokeo
Diverter is installed in the armature of DC machine as per manufacturer specifications.
Tathmini ya maarifa
Knowledge evidence:
Detailed knowledge of:
Methods used: The students should explain how to:
- Install diverter resistor to the armature system.
Principles: The students should explain the principles of: Operation of D.C. machines.
Theories: The students should explain:
- The major parts of D.C. machine control.
- The power rating of D.C. machine control.
- The application of D.C. machine control.
Swali
What is the primary purpose of installing a diverter resistor in a DC motor armature circuit?
Ingia ili kuwasilisha jibu lako na lihesabiwe katika umahiri wako.
Ingia ili kufanya mazoeziMwalimu
Umekwama? Niulize chochote kuhusu mada hii.
Ingia ili kumuuliza Mwalimu wa AI wa Sonza kuhusu swali hili.
Ingia ili kuulizaMajadiliano
Hakuna maswali bado