Mada za sehemu hiiInstalling control system of DC machinesMada 3
- Installing diverter in the armature
- Installing varistor in the field winding
- Starting a D.C. machine by using an autotransformer starter
A diverter is a resistor connected in parallel with part of a DC machine's winding so that part of the current is diverted through it instead of through the winding. A diverter connected across the armature of a DC series motor lets a technician run the motor at speeds below its normal speed. A diverter does not limit starting current; that is the job of a starter, which puts resistance in series with the armature.
A diverter is an electrical component (typically a resistor or rheostat) connected in parallel with a circuit element to provide an alternative path for electric current. In DC machines, diverters are installed to:
- Control the current flowing through windings
- Regulate motor speed
- Adjust the output voltage of a compound generator (a diverter across its series field)
1. Series Field Diverter
Connected in parallel with the series field winding. This is the most common type used in series DC motors to reduce the effective field strength and increase motor speed.
2. Armature Diverter
Connected directly across the armature terminals. It diverts a portion of the supply current away from the armature. For the same load the motor then draws more current through its series field, the field becomes stronger and the speed falls. An armature diverter is therefore used on a series motor to obtain speeds below normal.
Ratings
A diverter is rated by its resistance (in ohms, usually adjustable in steps or by a sliding contact) and by the maximum current it can carry continuously (in amperes) or its power (in watts). Both figures are on its label. The current rating must be higher than the largest current the diverter will carry, otherwise it overheats and burns out.
Installing a diverter in the armature circuit serves the following purposes:
- Speed control below normal speed: Part of the line current bypasses the armature. To produce the same torque the motor takes more line current, which strengthens the series field and lowers the speed.
- Adjustable speed: With a variable diverter the speed can be changed in steps while the machine is in service, for example to move a load slowly.
- Simplicity: A diverter is cheap and easy to fit, but it turns electrical energy into heat, so it is used mainly on small motors or for short periods.
A diverter does not replace the starter. The motor still needs its starting resistance in series with the armature.
- Three basic types: in a series machine the field winding is in series with the armature; in a shunt machine it is in parallel with the armature; a compound machine has both a series and a shunt field. Series motors give very high starting torque (cranes, hoists, traction), shunt motors run at nearly constant speed (lathes, fans, pumps) and compound motors combine the two (presses, lifts, rolling mills).
- Speed: the speed of a DC motor is proportional to the back EMF divided by the field flux, N∝ΦEb. A stronger field gives a lower speed; a weaker field gives a higher speed. Speed regulation is the change in speed from no load to full load, given as a percentage of the full-load speed.
- Commutation: the commutator and brushes reverse the current in each armature coil as it passes a brush, so that the torque always acts in one direction. Poor commutation shows as sparking at the brushes.
- Armature reaction: the armature current produces its own magnetic field, which distorts and weakens the main field. It shifts the magnetic neutral axis and causes sparking unless the machine has interpoles or the brushes are set correctly.
The following tools and safety equipment are needed:
| Tools | Safety Gear |
|---|---|
| Rawl plugs | Safety goggles |
| Set of screwdrivers | Safety boots |
| Set of spanners | Leather gloves |
| Megger | Plastic gloves |
| Combination pliers | Overalls |
| Electrician's knife | |
| Clamp on meter | |
| Multimeter | |
| Insulation tester |
Step 1: Safety Preparation
- Wear all required safety gear (goggles, boots, gloves, overalls)
- Ensure the DC machine is completely disconnected from the power supply
- Lock out and tag out the power source
- Prove that no voltage is present at the machine terminals, using a voltage tester or multimeter that has just been checked on a known supply; check the tester again afterwards
- Wait until the machine has stopped completely before touching any part
Step 2: Inspect the Machine
- Visually examine the armature and its terminals
- Check for any visible damage to insulation
- Verify the armature winding is intact using a multimeter
Step 3: Prepare and Mount the Diverter
- Study the control diagram and the terminal markings of the machine so that you know exactly where the diverter fits in the circuit (an armature diverter goes across the armature terminals, usually marked A1 and A2)
- Select a diverter whose resistance and current rating suit the machine, using the manufacturer's manual
- Inspect the diverter for any physical damage
- Test the diverter's resistance using a multimeter
- Choose a position close to the control panel of the machine, on a firm surface that cannot burn and with free air around it, because a diverter gets hot in use
- Mark the fixing holes using the base of the diverter as a template and a spirit level, drill the holes, insert rawl plugs and screw the diverter down so that it is level and firm
Step 4: Connect the Diverter
- Connect one terminal of the diverter to one armature terminal
- Connect the other terminal of the diverter to the opposite armature terminal
- Ensure connections are secure and properly tightened
- Use cable rated for the diverter current, fit crimped lugs to the cable ends, and support the cable in conduit, trunking or clips
- Connect the metal case of the diverter to the earthing conductor
Step 5: Insulate Connections
- Apply proper insulation to all exposed connections
- Use insulating tape where necessary
- Ensure no bare conductors are visible
Step 6: Test the Installation
- Use an insulation tester (Megger) to check insulation resistance between the circuit and the machine frame; it should be at least 1 MΩ
- Measure the total resistance across the armature-diverter combination
- Verify the circuit is complete and correct
- Check for any short circuits
- When all tests are satisfactory and the work has been checked by your supervisor, remove the lock and tag and restore the supply. Run the motor on load with the diverter at its highest resistance, then reduce the resistance one step at a time. The speed should fall at each step. Use a clamp-on meter set to DC to confirm that the line current stays within the rated current of the motor and that the diverter current stays within the rating of the diverter
- Make any change to the connections only after isolating and proving dead again
A DC motor has an armature with a resistance of Ra=5Ω. A diverter resistor of Rd=15Ω is connected in parallel across the armature terminals.
Calculate the combined (equivalent) resistance of the armature and diverter together, with the motor at rest.
Using the parallel resistance formula:
Req1=Ra1+Rd1
Req1=51+151
Req1=153+151=154
Req=415=3.75Ω
With the machine isolated and at rest, a multimeter across the armature terminals should therefore read about 3.75 Ω instead of 5 Ω. A reading lower than that of the armature alone is a quick check that the diverter really is connected in parallel.
Find how the current divides when the motor is running. Suppose the motor is running on load, the line current is 20 A and the voltage across the armature is 150 V.
Diverter current: Id=15150=10A
Armature current: Ia=20−10=10A
Power turned into heat in the diverter: P=150×10=1500W
The diverter must therefore be rated for more than 10 A and 1500 W. This heat is wasted energy, which is why a diverter is mounted where air can cool it and is used mainly on small motors or for short periods.
- Always disconnect power before working on any electrical installation
- Use proper lock-out/tag-out procedures
- Test all circuits before energising
- Never run a series motor without its load: with little or no load its speed rises to a dangerous level
- Do not touch the diverter while it is in use or just after: it gets hot
- Keep loose clothing, hair and hands away from the shaft and coupling when the motor is running
- Wear appropriate personal protective equipment at all times
- Follow your institution's safety regulations
After installation, verify:
- All connections are tight and secure
- Insulation is properly applied
- Resistance values are within specification
- No short circuits exist between conductors
- The circuit is properly earthed where required
When the job is finished, collect the cable off-cuts and stripped insulation, put scrap copper aside for recycling, sweep up the drilling dust, wipe the tools and return them to the store, and put the meters back in their cases.
In Tanzania, some older workshop machines, hoists and battery-powered vehicles still use DC series motors. For example, a technician in a workshop in Arusha may fit a diverter across the armature of a DC series motor that drives a hoist, so that the load can be moved slowly when it must be positioned carefully. Knowing how to choose, mount, connect and test the diverter safely is part of installing the control system of such a machine.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
The student should be able to:
- Interpret control diagrams.
- Identify types and ratings of D.C. machine controls.
- Prepare the base of D.C. machine control.
- Mark the location for installing the machine D.C. control systems.
- Fix and align the D.C. machine control.
- Install and terminate cables of the D.C. machine control.
- Test the D.C. machine control.
- Apply safety precautions.
- Clean the workplace.
Tathmini ya matokeo
D.C. machines control fixed, installed, and functions as per the manufacturer’s manual specifications.
Tathmini ya maarifa
Knowledge evidence:
Detailed knowledge of:
Method used: The student should explain how to install the diverter in the armature.
Principles: The student should explain the principles relating to installing a diverter in the armature.
Theories: The student should explain:
- The three basic types of D.C. machines.
- The commutation process.
- Speed regulation applied to D.C. machines.
- The armature reaction in D.C. machines.
- The Application of different types of D.C. machines.
Circumstantial knowledge:
Detailed knowledge about:
- Safety precautions on maintaining the speed of D.C. machines.
Swali
What is the primary purpose of installing a diverter across the armature of a DC series motor?