Mada za sehemu hiiConducting corrective maintenance of cutting machinesMada 7
- Performing levelling of plastic cutting block
- Re-setting the cutting pressure
- Plugging the travelling head-cutting machine into its recommended power source
- Replacing the cutting block
- Replacing electrical plugs
- Servicing and/or replacing the circuit
- Positioning the cutting machine on a balanced flat surface
An electrical plug (also called a power plug or attachment plug) is a device that connects an electrical appliance to a power source. Over time, plugs can become worn, damaged, or loose, which creates safety hazards such as electrical shocks or fires. Replacing a faulty electrical plug is a basic maintenance skill every technician must know.
Different electrical plugs are used depending on the appliance and voltage requirement:
- Two-pin plug – Has two prongs (live and neutral). Used only for small double-insulated appliances, which are marked with a square inside a square. A machine with a metal body must never be fitted with a two-pin plug.
- Three-pin plug – Has three prongs (live, neutral, and earth). The third pin (earth) provides safety by grounding the appliance. Used for appliances with metal casings.
- Industrial plug – A large round plug with three, four or five pins, used on heavy machines, including many three-phase cutting machines. Only a qualified electrician may fit or replace this type.
In Tanzania the mains supply is about 230 volts, which can kill. The common plug is the three-pin plug with flat rectangular pins and a small cartridge fuse inside. The work described here is for that kind of plug on a single-phase machine or appliance, and it is done under the supervision of a teacher or a qualified electrician.
Before replacing a plug, gather the following:
- Screwdrivers (flat-head and Phillips)
- Wire strippers or a sharp knife
- Electrical pliers
- Fuse of the correct rating for the appliance
- Replacement plug (appropriate type for the appliance)
- Multimeter (for checking connections)
- Dust coat and industrial gloves
Always follow these safety rules before working with electrical plugs:
- Switch off the cutting machine at its own switch and wait for all moving parts to stop, then switch off the socket.
- Disconnect the machine by pulling the plug out of the socket, holding the plug and not the cable. Keep the plug where you can see it, so that nobody can put it back while you work.
- Never open or touch the inside of a plug that is still in a socket. Students do not work on live equipment.
- Wear protective gloves and a dust coat.
- Keep the work area dry and free from conductive materials.
- Have your finished work checked by the teacher or a qualified electrician before the plug goes back into a socket.
An open plug is one with a cracked, loose or missing cover, or with wires showing where the cable enters. It is dangerous because:
- Anyone who touches the exposed live parts can get an electric shock, which can stop the heart
- Loose strands can bridge two terminals and cause a short circuit, sparks and fire
- A loose connection heats up, melts the plug and burns the socket
- If the earth wire has come loose, the metal body of a faulty machine can become live
- The machine may stop and start by itself, spoiling the work and damaging the motor
A cracked, burnt or open plug must be replaced, never taped up.
Step 1: Remove the Old Plug
- Unscrew the cover of the damaged plug using the appropriate screwdriver.
- Loosen the terminal screws holding the wires in place.
- Carefully pull the wires free from the terminals.
- Inspect the wire ends for damage, burning, or loose strands. If the end of the cable is burnt, brittle or cut, cut it back to sound cable. If the damage runs along the cable, the whole cable must be replaced by an electrician.
Step 2: Prepare the New Plug
- Open the new plug cover by unscrewing it.
- Check that the new plug is the same type and rating as the old one.
- Pass the cable under the cable grip (with some plugs, through the cover first).
- Remove about 4 cm of the outer sheath, taking care not to cut the insulation of the wires inside.
- Cut each wire to the length needed to reach its terminal with a little slack, leaving the earth wire the longest, and strip about 6 mm of insulation from each end.
- Twist the bare strands of each wire tightly together so that none stick out.
Step 3: Connect the Wires to the Terminals
For a three-pin plug, connect each wire to its correct terminal:
- Brown or Red wire → Live terminal (L) – the terminal joined to the fuse, at the bottom right as you look into the open plug, marked "L"
- Blue or Black wire → Neutral terminal (N) – at the bottom left, marked "N"
- Green-and-yellow (green/yellow striped) wire → Earth terminal (E) – the terminal marked with the earth symbol (⏚), at the top centre, joined to the longest pin
Brown, blue and green-and-yellow are the present colours. Red (live), black (neutral) and plain green (earth) are found only on old cables. Always follow the letters L, N and E marked inside the plug. Push each bare end fully into its terminal, tighten the screw firmly, then pull gently on each wire to check that it is held.
For a two-pin plug:
- Connect the brown (live) wire and blue (neutral) wire to their respective terminals.
Step 4: Secure the Cable
- Tighten the cable grip (strain relief) over the outer sheath of the cable, not over the separate coloured wires. This prevents the wires from being pulled loose during use.
- Check that the fuse has the rating shown on the machine's rating plate or in its manual, and that it is firmly clipped in. Never replace a fuse with wire, foil or a nail.
- Look once more: no bare strands outside the terminals, each wire in its correct terminal, and no wire trapped under the cover.
Step 5: Reassemble and Test
- Screw the plug cover back on tightly.
- Have the plug checked by the teacher or a qualified electrician. With the plug still out of the socket, a multimeter set to continuity can confirm that the earth pin is connected to the metal body of the machine.
- Plug in, switch on the socket and then the machine, and check that it runs normally.
- Never measure voltage inside a plug or at its pins while it is connected to the supply. If the plug becomes warm, sparks or smells of burning, switch off at once and report it.
Step 6: Clean Up and Store
- Pick up every offcut of wire and insulation; loose strands of copper can cause short circuits. Put them and the old plug in the waste bin, so that nobody reuses a damaged plug.
- Wipe the tools and return the screwdrivers, pliers and multimeter to their places.
- Wipe dust from the machine's cable and make sure it does not lie where it can be cut, crushed or tripped over.
A Form 2 leather technician notices that the electric cutting machine in the workshop does not start. Upon inspection, the three-pin plug on the machine is found to be burnt at the live terminal. The technician follows these steps:
- Switches off the main power and disconnects the plug from the socket.
- Opens the burnt plug and finds the brown (live) wire disconnected and its insulation melted.
- Cuts the cable back past the melted part to clean, undamaged wire, prepares the three wire ends and strips about 6 mm of insulation from each using wire strippers. The burnt plug is thrown away and a new plug of the same rating is used.
- Connects the brown wire to the "L" terminal, the blue wire to the "N" terminal, and the green-and-yellow wire to the "E" terminal.
- Tightens the cable grip over the outer sheath, checks the fuse rating, reassembles the plug and has it checked by the teacher.
- Tests the machine by switching on the power. The machine starts successfully.
- Do not connect the live and neutral wires to the wrong terminals.
- Do not leave bare wire strands exposed outside the terminal.
- Do not leave terminal screws loose, as a loose connection overheats. Tighten them firmly without cutting the strands.
- Do not use a damaged or wrong-type plug for the appliance.
- Do not join or repair a damaged cable with insulation tape.
- Do not try to replace the plug of a three-phase machine; call a qualified electrician.
In a small tailoring workshop in Arusha, a leather goods maker uses an electric sewing machine daily. When the machine's plug becomes loose and sparks, the technician can replace it using the correct three-pin plug, ensuring safe operation and avoiding costly downtime or electrical accidents in the workshop.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
The student should be able to:
- Observe the safety precautions for cutting machines
- Replace an electrical plug in its position
- Observe safety
- Clean tools, equipment, and machines
- Store tools and equipment
Tathmini ya matokeo
Electrical plugs are replaced in their recommended position properly
Tathmini ya maarifa
Knowledge evidence:
Detailed knowledge of:
Method used: The student should explain clearly how to: Replace electrical plugs in its recommended position
Principles: The student should explain the principles of:
- Replacing electrical plugs
Theories: The student should explain:
- The effects of open electrical plugs
Circumstantial knowledge:
Detailed knowledge of:
- Safe handling of electrical plugs
Swali
Why must a machine with a metal body be fitted with a three-pin plug and never a two-pin plug?
Ingia ili kuwasilisha jibu lako na lihesabiwe katika umahiri wako.
Ingia ili kufanya mazoeziMwalimu
Umekwama? Niulize chochote kuhusu mada hii.
Ingia ili kumuuliza Mwalimu wa AI wa Sonza kuhusu swali hili.
Ingia ili kuulizaMajadiliano
Hakuna maswali bado