Mada za sehemu hiiRepairing domestic refrigeratorsMada 6
Control equipment in a domestic refrigerator are the devices that regulate the operation of the compressor, fan, and other components to ensure the refrigerator maintains the desired temperature and operates safely. These components work together as a control system. When any of these devices fail, the refrigerator may not cool properly, may run continuously, or may not start at all. Repairing control equipment involves identifying faulty components, testing them with appropriate tools, and replacing or adjusting them to restore proper operation.
Control equipment refers to the electrical and mechanical devices that start, stop, and regulate the various parts of a refrigeration system. In a domestic refrigerator, these devices ensure that:
- The compressor runs only when cooling is needed
- The temperature inside the cabinet stays within the set range
- The compressor is protected from electrical overload and overheating
- The evaporator fan and condenser fan operate correctly
- Defrost cycles occur at proper intervals
Without these controls, the refrigerator would either run continuously or fail to run at all, leading to spoiled food or damage to the system.
2.1 Temperature Control (Thermostat)
The thermostat senses the temperature inside the refrigerator and turns the compressor on or off to maintain the set temperature. It consists of a temperature-sensitive bulb (usually placed in the evaporator compartment) connected to a switch through a capillary tube. When the temperature rises above the setting, the bulb expands and closes the circuit to start the compressor. When the temperature drops to the desired level, the bulb contracts and opens the circuit to stop the compressor.
2.2 Starting and Running Devices
Start Relay: The start relay helps the compressor motor start by temporarily connecting the start winding. Once the motor reaches operating speed, the relay disconnects the start winding.
Overload Protector: This device protects the compressor motor from overheating or drawing excessive current. If the motor draws too much current due to a fault, the overload trips and cuts power to the compressor.
2.3 Fan Motors
Evaporator Fan: Circulates air over the evaporator coils to cool the refrigerator interior.
Condenser Fan: Draws air across the condenser coils to dissipate heat removed from the cabinet.
2.4 Defrost Control
Defrost Timer: Automatically initiates defrost cycles at set intervals to remove frost buildup on the evaporator coils.
Defrost Thermostat: Senses the temperature of the evaporator during defrost and terminates the defrost cycle when the coils reach a safe temperature (usually around 15°C to 21°C).
2.5 Door Switch
The door switch activates the interior light when the door opens and may also control the evaporator fan in some models.
Step 1: Observe the Problem and Gather Information
Before touching any component, observe how the refrigerator is behaving. Check if:
- The compressor runs continuously or does not start
- The interior temperature is too warm or too cold
- The fan is noisy or not running
- Unusual sounds or vibrations are present
Ask the user about the problem and when it started. This information helps narrow down which control device is likely faulty.
Step 2: Ensure Safety
Before beginning any repair:
- Unplug the refrigerator from the power supply
- Wear safety boots and overalls to protect yourself
- Ensure the work area is dry and well-lit
- Use insulated tools when working with electrical components
Step 3: Test Control Components
Use appropriate tools to test each control device:
Testing a Thermostat: Set the thermostat to the coldest position. Use a continuity tester or multimeter to check if there is continuity (a complete circuit) through the thermostat when it is calling for cooling. If there is no continuity, the thermostat is defective and should be replaced.
Testing a Start Relay: Remove the relay and shake it gently. If you hear a rattling sound, the relay may be faulty. Use a multimeter to check for continuity between the start (S) and common (C) terminals. An open circuit indicates a faulty relay.
Testing an Overload Protector: Use a multimeter to check for continuity across the overload terminals. If there is no continuity, the overload is tripped or defective and must be replaced.
Testing Fan Motors: Disconnect the fan motor and use a multimeter to check the resistance of the winding. If the winding shows infinite resistance (open circuit) or zero resistance (shorted), the motor is faulty. Also check that the fan blades spin freely.
Step 4: Replace Faulty Components
After identifying the faulty control device:
- Disconnect the wires and note their positions (draw a diagram if necessary)
- Remove the defective component
- Install the new component, ensuring correct wire connections
- Secure all connections properly
Step 5: Test the Repair
Plug the refrigerator back in and observe its operation:
- The compressor should start and run normally
- The interior temperature should reach the desired setting within a few hours
- All fans should operate quietly
- No unusual sounds or vibrations should occur
Use a thermometer to verify that the refrigerator is maintaining the correct temperature (typically 3°C to 5°C for fresh food compartment).
A household in Arusha reports that their domestic refrigerator is not cooling. The compressor does not start at all. Using the systematic approach:
-
Safety first: Unplug the refrigerator and wear protective gear.
-
Initial check: Confirm the compressor does not run and no sound comes from the relay.
-
Testing: The technician tests the start relay with a multimeter and finds no continuity between the start and common terminals. The overload protector also shows no continuity.
-
Diagnosis: Both the start relay and overload protector are faulty, preventing the compressor from starting.
-
Repair: The technician replaces both the start relay and overload protector with new matching parts.
-
Testing: After replacement, the refrigerator is plugged in and the compressor starts running. After 24 hours, the interior temperature reaches 4°C, confirming successful repair.
In Tanzania, domestic refrigerators are essential in households, shops, and small businesses like butcheries and fish markets. A technician who can repair control equipment helps community members avoid replacing expensive refrigerators. For example, replacing a faulty thermostat or start relay in Dar es Salaam costs around TZS 15,000 to 30,000 in parts, while a new domestic refrigerator costs over TZS 400,000. This skill saves families money and keeps perishable foods like fresh milk and vegetables from spoiling during hot weather.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
- Select tools and equipment
- Perform diagnostic trouble shooting
- Repair refrigerant leaks
- Repair damaged cabinet
- Repair thermostatic expansion valve
- Test run
- Clean workplace
- Store tools and equipment
Tathmini ya matokeo
Demonstrate the ability of identify fault of control equipment and repair control equipment in domestic refrigerator conforms to technical specifications
Tathmini ya maarifa
Knowledge evidence:
Detailed knowledge of:
Method used: The student should explain how to:
- Control refrigerant floor
- Measure pressure quantities
- Perform leak detection
Principles: The students should explain the principles of:
- Control equipment
- Basic refrigerant cycle
Theories: The student should explain:
- Repair concept
Detailed knowledge about:
- Different refrigerant application in control equipment
- Refrigerant properties
- Electrical circuits
- Safe handling of control equipment and working tools
Swali
What is the main purpose of control equipment in a domestic refrigerator?
Ingia ili kuwasilisha jibu lako na lihesabiwe katika umahiri wako.
Ingia ili kufanya mazoeziMwalimu
Umekwama? Niulize chochote kuhusu mada hii.
Ingia ili kumuuliza Mwalimu wa AI wa Sonza kuhusu swali hili.
Ingia ili kuulizaMajadiliano
Hakuna maswali bado