Mada za sehemu hiiRepairing domestic refrigeratorsMada 6
Compressor Replacement in Domestic Refrigerators
The compressor is the heart of a refrigeration system. It is an electric motor that compresses the refrigerant gas, raising its pressure and temperature. This compression forces the refrigerant to circulate through the condenser, expansion valve, and evaporator, enabling the cooling process in domestic refrigerators and air conditioners.
Compressors may need replacement when they develop faults such as:
- Electrical failure – burnt-out motor windings or damaged start relays
- Mechanical failure – seized pistons or broken valves inside the compressor
- Refrigerant leaks – internal leaks that contaminate the compressor oil
- Excessive noise or vibration – indicating internal damage
A faulty compressor will cause the refrigerator to stop cooling or make unusual knocking sounds.
Before replacing a compressor, gather these tools:
- Electro mechanical tool kit (screwdrivers, wrenches, pliers)
- Digital or analog multimeter (to test electrical components)
- Oxy-acetylene welding set (for brazing new connections)
- Gauge manifold (to measure refrigerant pressures)
- Vacuum pump (to remove moisture and air from the system)
- Refrigerant leak detector (to check for leaks after installation)
- Recovery unit and recovery cylinder (to safely collect old refrigerant)
- Refrigerant identifier (to verify refrigerant type)
- Compressor valve key (to open and close service valves)
- Safety gear: boots, overall, gloves, and goggles
Step 1: Safety Preparation
Put on safety boots, overall, gloves, and goggles. Disconnect the refrigerator from the electrical supply. Ensure the work area is well-ventilated.
Step 2: Recover the Refrigerant
Connect the recovery unit to the service valves. Use the refrigerant leak detector to confirm no leaks in the system. Carefully recover the refrigerant into the recovery cylinder according to safety procedures. This step protects the environment and complies with regulations.
Step 3: Remove the Old Compressor
Use the compressor valve key to close the service valves. Disconnect the electrical wiring from the old compressor, noting the connections. Remove the mounting bolts holding the compressor in place. Disconnect the suction and discharge lines using appropriate tools.
Step 4: Install the New Compressor
Mount the new compressor securely using the mounting bolts. Connect the suction and discharge lines properly. Braze the connections using the oxy-acetylene welding set if needed. Reconnect the electrical wiring to the correct terminals.
Step 5: Evacuate the System
Connect the vacuum pump to the system through the gauge manifold. Run the vacuum pump for at least 30 minutes to remove moisture and air. Close the vacuum pump valve and check that the system holds a vacuum.
Step 6: Charge with Refrigerant
Identify the correct refrigerant type using the refrigerant identifier. Charge the system with the specified amount of refrigerant through the service valve. Use the gauge manifold to verify proper high and low pressure readings.
Step 7: Test for Leaks and Operation
Use the leak detector to check all connections for refrigerant leaks. Plug in the refrigerator and observe the cooling cycle. Verify that the compressor runs smoothly without excessive noise or vibration.
A domestic refrigerator in a shop in Dar es Salaam stops cooling. The technician tests the compressor with a multimeter and finds the motor winding is open-circuited (infinite resistance). This indicates the compressor motor is burnt out and cannot be repaired.
The technician follows these steps:
- Recovers the old R-134a refrigerant safely
- Removes the faulty compressor
- Installs a new compressor of the same type
- Evacuates the system for 30 minutes
- Recharges with 150 grams of R-134a
- Tests for leaks and confirms proper cooling
The refrigerator now works correctly.
In Tanzania, a refrigerator repair technician in Arusha or Mwanza uses compressor replacement skills to service commercial refrigerators in shops, restaurants, and small businesses. For example, a food vendor whose refrigerator compressor fails can pay a technician around TSh 150,000 to TSh 300,000 for replacement and refilling, restoring perishable goods storage and preventing financial loss from spoiled food.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
- Select tools and equipment
- Perform diagnostic trouble shooting
- Replace compressor
- Repair scroll compressor
- Charge refrigerant
- Test run
- Clean workplace
- Store tools and equipment
Tathmini ya matokeo
Demonstrate the ability of identify size of compressor and replacing compressor in domestic refrigerator conforms to technical specifications
Tathmini ya maarifa
Knowledge evidence:
Detailed knowledge of:
Method used: The student should explain how to:
- Control refrigerant being charged
- Measure compressor electrical and mechanical party
- Perform leak detection
- Join copper tubing
Principles: The student should explain the principles of: (dd) Heat transfer (ee) Basic refrigerant cooling cycle (ff) Scroll compressors (gg) Reciprocating compressors
Theories: The student should explain:
- Replace concept
Detailed knowledge about:
- Different refrigerant application
- Refrigerant properties
- Safe handling of refrigerants and tools
Swali
What is the primary role of the compressor in a domestic refrigerator?
Ingia ili kuwasilisha jibu lako na lihesabiwe katika umahiri wako.
Ingia ili kufanya mazoeziMwalimu
Umekwama? Niulize chochote kuhusu mada hii.
Ingia ili kumuuliza Mwalimu wa AI wa Sonza kuhusu swali hili.
Ingia ili kuulizaMajadiliano
Hakuna maswali bado