Mada za sehemu hiiPerforming rewinding of electric motorsMada 3
- Rewinding single-phase motors
- Rewinding three-phase motors
- Rewinding D.C. motors
Rewinding a D.C. motor is the process of removing damaged or burnt copper windings from the armature and field coils and replacing them with new insulated wire according to the original specifications. This restores the motor's performance and extends its service life.
D.C. motors may require rewinding when:
- The windings are burnt or shorted due to overload, poor ventilation, or electrical faults
- Insulation deteriorates from age, heat, moisture, or chemical exposure
- The motor fails to start, runs slowly, or draws excessive current
- Physical damage occurs to the coils from impact or vibration
Rewinding is often more economical than replacing the entire motor, especially for large or specialized D.C. motors used in industrial applications.
The following tools are needed for rewinding work:
- Electrician's tool kit (screwdrivers, pliers, cutters)
- Coil tripping chisel and commutator slotting files
- Wire cutters and wire strippers
- Tubing cutter and propane torch
- Hammers and mallets for tapping and shaping
- Slot cleaning brushes and wedge drivers
- Bearing puller for removing old bearings
- Ohmmeter or continuity tester for checking windings
- Coil making machine (if available)
- Safety gear: insulated gloves, safety glasses, ear protection
1. Preliminary Inspection and Testing
Before disassembling, visually inspect the motor for damage. Use an ohmmeter to check winding continuity and insulation resistance. Record the original winding data: number of coils, turns per coil, wire gauge, and coil connections.
2. Disassembly
Remove the motor from its mounting and disconnect all wiring. Carefully remove the armature (rotor) and field coils. Use a bearing puller to remove worn bearings. Mark all components for correct reassembly orientation.
3. Removing Old Windings
Use a coil tripping chisel to cut and remove the damaged windings from the slots. Clean the slots thoroughly using slot cleaning brushes. Remove all old insulation, wedges, and debris. Check the commutator for wear and smooth any rough segments with commutator slotting files.
4. Preparing the Core
Inspect the armature core for damage or bent laminations. Clean and dry the slots. Apply new slot insulation (liner paper) to protect the windings from the core.
5. Winding the Coils
Using the original specifications, wind new coils using appropriate gauge magnet wire. Maintain proper tension while winding. Form coils to match the original shape and size. Insert coils into slots carefully, ensuring correct lead connections.
6. Connecting and Taping
Connect coil ends according to the original circuit diagram (series, shunt, or compound configuration). Secure connections with crimp connectors and insulate with tape. Apply wedges to hold windings firmly in slots.
7. Testing and Finishing
Test the rewound motor for continuity, insulation resistance, and correct resistance values. If satisfactory, apply insulating varnish and bake (if facilities available). Reassemble the motor and run a no-load test.
- Always disconnect power before working on motors
- Wear safety glasses when cutting or tapping windings
- Use insulated tools for electrical testing
- Work in a clean, well-lit area
- Handle the commutator carefully to avoid damage
In Tanzania, rewinding D.C. motors is commonly practiced in small electrical workshops found in markets such as Mwenge in Dar es Salaam or along the main roads in Arusha. A small workshop owner may rewind a 1 HP D.C. motor from a water pump or industrial machine for about TSh 80,000 to 150,000, which is far cheaper than buying a new motor that could cost TSh 500,000 or more. This skill enables electrical technicians to provide affordable repair services to local businesses and farmers who depend on D.C. motor-driven equipment.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
- Select tools, equipment, and safety gear.
- Record nameplate data.
- Disassemble motor.
- Draw a winding diagram.
- Remove old winding and note down the number of turns.
- Clean gaps/slots.
- Insert the insulating paper in the stator.
- Wind new coil.
- Bind the coil and varnish the motor.
- Assemble the back bearing and fan.
- Perform necessary measurements and tests for verification of termination.
- Test the rewoun d motors.
- Observe safety precautions.
- Clean tools, equipment and work area.
Tathmini ya matokeo
D.C. motors rewound as per technical specifications, NEMA standards and IEE Regulations.
Tathmini ya maarifa
Knowledge evidence:
Detailed knowledge of:
Method used: The student should explain how to rewind D.C. motors.
Principles: The student should explain the principles related to rewinding D.C. motors.
Theories: The student should explain:
- The types of motor rewinding.
- Taking data and calculation.
- Core testing.
- Winding stripping procedures.
- Core preparation.
- Coil making.
- Winding insulation and coil insertion.
- Internal connections
- Lacing and bracing of windings.
- Inspection of untreated windings
- Testing untreated and treated windings.
- Winding treatment.
- Circumstantial knowledge
- Detailed knowledge about:
- Safety precautions when handling motors.
- Properties of materials
Swali
Which of the following is a reason why a D.C. motor may require rewinding?
Ingia ili kuwasilisha jibu lako na lihesabiwe katika umahiri wako.
Ingia ili kufanya mazoeziMwalimu
Umekwama? Niulize chochote kuhusu mada hii.
Ingia ili kumuuliza Mwalimu wa AI wa Sonza kuhusu swali hili.
Ingia ili kuulizaMajadiliano
Hakuna maswali bado