Mada za sehemu hiiDesigning and making ice making machineMada 7
A refrigerant pipe circuit is the network of tubes that carries the refrigerant through a refrigeration system, connecting the compressor, condenser, evaporator, and other components. When you construct this circuit, you are building the pathway through which the refrigerant flows to absorb heat from one place and release it in another, just like in a domestic refrigerator or the ice-making machine you are designing.
The pipe circuit forms a closed loop that allows the refrigerant to circulate continuously. It connects the four main components of a refrigeration system:
- Compressor – squeezes the refrigerant, raising its pressure and temperature
- Condenser – releases heat to the surroundings and turns the refrigerant into liquid
- Expansion valve – reduces the pressure and temperature of the liquid refrigerant
- Evaporator – absorbs heat from the space to be cooled, turning the refrigerant back into gas
The pipe circuit must be properly sized, connected, and sealed to ensure the refrigerant flows smoothly without leaks.
When constructing a refrigerant pipe circuit, the following tools and equipment are required:
- Pipe bender – for bending pipes without kinking them
- Cutting tools – shearing machine or pipe cutters for cutting pipes to length
- Drilling machine – for making holes to mount components
- Oxy-acetylene plant – for brazing and welding pipe connections
- Soldering gun – for smaller soldering work
- Resistance welding machine – for joining metal components
- Plumbing tools – wrenches, pliers, and flaring tools
- Manifold gauge – for testing pressure in the system
- Vacuum pump – for removing moisture and air from the system
- Tape measure – for accurate measurements
- Safety gear – gloves, goggles, fire extinguisher, and protective clothing
- Electromechanical tool kit – for general assembly work
Step 1: Planning and Measuring
First, plan the layout of the pipe circuit based on the design of your ice-making machine. Measure the distances between components (compressor, condenser, evaporator, expansion valve) and determine the pipe lengths needed. Make sure to leave enough space for fittings and bends.
Step 2: Cutting the Pipes
Use the shearing machine or pipe cutters to cut the pipes to the measured lengths. Ensure the cuts are clean and square so that the pipes fit together properly.
Step 3: Bending the Pipes
Use the bending machine to form the necessary bends in the pipes. Proper bending avoids kinks that would restrict refrigerant flow. Common bends include:
- 90-degree bends for changing direction
- U-bends for connecting parallel components
Step 4: Preparing Pipe Ends
Prepare the pipe ends by cleaning them thoroughly. Use a flaring tool to create a flared end where the pipe will connect to a component. This ensures a tight seal when the connection is made.
Step 5: Joining the Pipes
Connect the pipes using appropriate fittings such as couplings, elbows, and tees. Use the oxy-acetylene plant for brazing large pipes or the soldering gun for smaller joints. Make sure all joints are properly sealed to prevent refrigerant leaks.
Step 6: Installing Components
Install the compressor, condenser, evaporator, and expansion valve at their designated positions. Connect the pipe circuit to each component using the proper fittings and ensure all connections are secure.
Step 7: Testing the Circuit
After assembling, use the manifold gauge to check the system pressure. Connect the vacuum pump to remove any air or moisture trapped in the system. This step is critical because moisture and air can cause blockages and reduce the system's efficiency.
Step 8: Charging with Refrigerant
Once the circuit is tested and proven leak-free, charge the system with the correct type and amount of refrigerant as specified in the design.
- Always wear safety gloves and goggles when cutting, bending, or welding pipes
- Keep a fire extinguisher nearby when using the oxy-acetylene plant
- Ensure good ventilation in the work area
- Handle refrigerant with care – it can be harmful if inhaled or if it contacts the skin
- Disconnect power supplies before working on electrical components
Suppose you are constructing a refrigerant pipe circuit for a small ice-making machine. The distance from the compressor to the condenser is 40 cm, from the condenser to the expansion valve is 30 cm, and from the expansion valve to the evaporator is 25 cm. You also need to include three 90-degree bends and two U-bends.
Calculation:
- Straight pipe sections: 40 + 30 + 25 = 95 cm
- Estimated additional length for bends: Each 90-degree bend adds approximately 5 cm, and each U-bend adds approximately 10 cm.
- Three 90-degree bends = 3 × 5 = 15 cm
- Two U-bends = 2 × 10 = 20 cm
- Total pipe length needed = 95 + 15 + 20 = 130 cm
You should cut pipes totaling approximately 130 cm, accounting for some extra length as waste during cutting and fitting.
In Tanzania, constructing a properly functioning refrigerant pipe circuit is essential for repairing and maintaining refrigerators in homes, shops, and small businesses. For example, a technician in Dar es Salaam or Mwanza who can construct and repair refrigerant pipe circuits can service the many small shops that rely on refrigerators to keep drinks and food fresh, helping business owners reduce losses from spoiled goods worth hundreds of thousands of Tanzanian shillings.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
- Identify materials, tools and equipment required
- Draw a mechanical working drawing
- Prepare body structure of the ice making system
- Assemble parts to form the machine
- Mount the mechanical refrigeration components
- Perform wiring circuits for Primary and Secondary circuits
- Perform plumbing
- Evacuate and charge with refrigerant
- Perform spray painting
- Apply safety gears appropriately
- Clean workplace, tools and equipment
- Store tools and equipment
- Commission the machine
Tathmini ya matokeo
Designed and made ice maker conform to technical and aesthetic specifications
Tathmini ya maarifa
Knowledge Evidence:
Detailed knowledge of:
Method used: The student should explain how to:
- Plan work
- Measure electrical to pressure quantities
- Determine system character
- Make different types of ice making units
- Form ice
Principles: The student should explain the principles of: (j) Heat transfer and exchange (k) System operating characteristics (l) Design parameters
Theories: The student should explain:
- Components functions
- Refrigeration pipe circuit
- Refrigerants properties
- Heat load estimation
Circumstantial knowledge:
Detailed knowledge about:
- Safe handling of working tools and equipment machines
- Plumbing
- Environmental Regulations
Swali
Which four components are connected by the refrigerant pipe circuit in a refrigeration system?
Ingia ili kuwasilisha jibu lako na lihesabiwe katika umahiri wako.
Ingia ili kufanya mazoeziMwalimu
Umekwama? Niulize chochote kuhusu mada hii.
Ingia ili kumuuliza Mwalimu wa AI wa Sonza kuhusu swali hili.
Ingia ili kuulizaMajadiliano
Hakuna maswali bado