Mada za sehemu hiiServicing domestic freezersMada 4
- Replacing evaporator coil
- Replacing compressor unit
- Replacing control elements
- Charging with refrigerant
The compressor is the most important part of a refrigeration system. It is often called the "heart" of the refrigerator because it circulates refrigerant throughout the whole system. The compressor takes low-pressure, low-temperature refrigerant gas from the evaporator and squeezes it into high-pressure, high-temperature gas. This compression raises the refrigerant's temperature so that heat can be released through the condenser, and the cooling cycle can continue.
In domestic refrigerators and freezers, the compressor is usually located at the back or bottom of the unit. When the compressor fails, the refrigerator stops cooling and the food inside spoils.
A compressor may need replacement when:
- The motor fails to start and you hear a humming sound
- The compressor makes loud or unusual noises during operation
- The refrigerator does not cool even though the condenser coils are hot
- There is visible damage to the compressor housing or burnt electrical terminals
- The compressor runs continuously without achieving the desired temperature
Before beginning any replacement work, ensure you have:
- Electro mechanical tool kit (screwdrivers, wrenches, pliers)
- Digital or analog multimeter (to test electrical connections)
- Oxy-acetylene welding set (for brazing copper lines)
- Gauge manifold (to read system pressures)
- Vacuum pump (to remove air and moisture)
- Refrigerant leak detector (to check for leaks)
- Recovery unit and recovery cylinder (to safely remove old refrigerant)
- Refrigerant identifier (to verify refrigerant type)
- Safety boots, overall, gloves, and goggles (personal protective equipment)
- Compressor valve key (to open and close service valves)
When working with refrigeration systems, always follow these safety rules:
- Disconnect the refrigerator from the electrical supply before starting work
- Wear safety goggles, gloves, and boots at all times
- Never release refrigerant into the atmosphere — always recover it using approved equipment
- Allow the system to equalize pressure before opening any valves
- Keep the work area clean and free of flammable materials when using oxy-acetylene equipment
Step 1: Disconnect Power and Prepare
Unplug the refrigerator from the electrical socket. Place the unit in a well-ventilated area. Remove any panels needed to access the compressor.
Step 2: Recover the Refrigerant
Connect the recovery unit to the service valves. Use the recovery cylinder to safely draw out all refrigerant from the system. This step is required by law — releasing refrigerant harms the ozone layer and the environment.
Step 3: Remove the Old Compressor
Use the compressor valve key to close the service valves. Disconnect the electrical wiring carefully, noting how each wire is connected. Use the oxy-acetylene torch to unsolder the suction and discharge lines from the compressor. Remove the mounting bolts and take out the old compressor.
Step 4: Install the New Compressor
Mount the new compressor securely using the mounting bolts. Reconnect the suction and discharge lines by brazing them with the oxy-acetylene torch. Make sure all connections are tight and clean.
Step 5: Leak Test
Apply leak detector solution or use an electronic leak detector on all joints and connections. Watch for any bubbles or alarms that indicate refrigerant is escaping. If a leak is found, repair it before proceeding.
Step 6: Evacuate the System
Connect the vacuum pump to the system and run it for at least 30 minutes. This removes air and moisture that would cause problems later. Watch the gauge manifold to ensure the system reaches a deep vacuum.
Step 7: Charge with Refrigerant
Weigh the correct amount of refrigerant using a charging scale. The correct charge amount is usually written on the compressor label or in the manufacturer's instructions. Slowly add the refrigerant to the system.
Step 8: Test the System
Plug the refrigerator back in. Let it run for several hours. Check that the freezer reaches -18°C and the fresh food compartment reaches around 4°C. Listen for normal compressor operation and feel that the condenser is warm.
A refrigerator in a household in Mwanza stops cooling. The technician tests the electrical connections with a multimeter and finds the compressor windings are open (broken). The technician recovers 60 grams of R-134a refrigerant, removes the faulty 1/6 HP compressor, and installs a new replacement compressor of the same rating. After brazing the connections, performing a leak test, and evacuating for 30 minutes, the technician charges 60 grams of R-134a back into the system. After two hours of operation, the freezer temperature drops to -18°C, confirming the replacement was successful.
In Tanzania, many small businesses such as fish vendors in Kigoma, butchers in Arusha, and pharmacy shops in Dar es Salaam depend on domestic refrigerators and freezers to keep their products fresh. When a compressor fails, a trained technician can replace it and restore the cooling system, preventing thousands of shillings in lost stock. This skill also creates employment opportunities for young people who complete refrigeration and air conditioning courses and start their own repair businesses.
Jinsi utakavyotathminiwaTathmini ya mchakato · Tathmini ya matokeo · Tathmini ya maarifa
Tathmini ya mchakato
- Select tools and equipment
- Perform diagnostic trouble shooting
- Replace compressor
- Repair scroll compressor
- Charge refrigerant
- Test run
- Clean workplace
- Store tools and equipment
Tathmini ya matokeo
Demonstrate the ability of identify size of compressor and replacing compressor in domestic refrigerator conforms to technical specifications
Tathmini ya maarifa
Knowledge evidence:
Detailed knowledge of:
Method used: The student should explain how to:
- Control refrigerant being charged
- Measure compressor electrical and mechanical party
- Perform leak detection
- Join copper tubing
Principles: The student should explain the principles of: (d) Heat transfer (e) Basic refrigerant cooling cycle (f) Scroll compressors (g) Reciprocating compressors
Theories: The student should explain:
- Replace concept
Detailed knowledge about:
- Different refrigerant application Refrigerant properties
- Safe handling of refrigerants and tools
Swali
What is the primary function of the compressor in a refrigeration system?
Ingia ili kuwasilisha jibu lako na lihesabiwe katika umahiri wako.
Ingia ili kufanya mazoeziMwalimu
Umekwama? Niulize chochote kuhusu mada hii.
Ingia ili kumuuliza Mwalimu wa AI wa Sonza kuhusu swali hili.
Ingia ili kuulizaMajadiliano